![Fujitsu AUXG30KRLB Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/fujitsu/auxg30krlb/auxg30krlb_service-instruction_2343789013.webp)
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOYG30KATA
AOYG36KATA
A zone
55 rps
B zone
52 rps
C zone
47 rps
D zone
39 rps
E zone
33 rps
F zone
25 rps
G zone
18 rps
H zone
20 rps
I zone
20 rps
J zone
21 rps
K zone
24 rps
AOYG45KATA
A zone
60 rps
B zone
57 rps
C zone
48 rps
D zone
36 rps
E zone
27 rps
F zone
24 rps
G zone
20 rps
H zone
20 rps
I zone
20 rps
J zone
26 rps
K zone
30 rps
AOYG54KATA
A zone
50 rps
B zone
47 rps
C zone
40 rps
D zone
30 rps
E zone
22 rps
F zone
20 rps
G zone
16 rps
H zone
16 rps
I zone
17 rps
J zone
23 rps
K zone
28 rps
1-5. Compressor frequency limitation by outdoor temperature