En-2

2.4. Accessories

The following installation accessories are supplied. Use them as required.

Name and Shape

Q’ty

Name and Shape

Q’ty

Operating manual

1

Tapping screw 

(Large)

5

Installation manual 

(This manual)

1

Tapping screw 

(Small)

2

Wall hook bracket

1

Air cleaning filter

2

Cloth tape

1

Filter holders

2

Remote controller

1

Seal A

1

Battery

2

Cable clamper and screw

 

 

For the installation of the wired 

remote controller (Option)

.

1

Remote controller holder

1

The following items are necessary to install this air conditioner. (The items are not includ-

ed with the air conditioner and must be purchased separately.)

Name 

Q’ty

Name 

Q’ty

Connection pipe assembly

1

Wall cap

1

Connection cable (4-conductor)

1

Saddle

1 set

Wall pipe

1

Drain hose

1

Decorative tape

1

Tapping screws

1 set

Vinyl tape

1

Sealant

1

2.5. Additional materials required for installation

A. Refrigeration (armored) tape

B. Insulated staples or clamps for connecting wire (See your local electrical codes.)

C. Putty

D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping

2.6. Optional parts

Refer to each installation manual for the method of installing optional parts.

Parts name

Model No.

Application

Wired Remote Controller

UTY-RVNUM

For air conditioner operation

Wired Remote Controller

UTY-RNRUZ1

For air conditioner operation

Simple Remote Controller

UTY-RSNUM

For air conditioner operation

External connect kit

UTY-XWZX

For control input/output port

External input and output PCB*

UTY-XCSXZ1

For connecting external devices

PCB kit

UTY-GXXB

For the installation of UTY-XCSXZ1

* Optional PCB kit (UTY-GXXB) is necessary for the installation.

3.  GENERAL SPECIFICATIONS

This INSTALLATION MANUAL briefly outlines where and how to install the air conditioning system. 

Please read over the entire set of instructions for the indoor and outdoor units and make sure all 

accessory parts listed are with the system before beginning.

3.1. Type of copper pipe and insulation material

 CAUTION

Refer to the installation manual for the outdoor unit for description of allowable pipe length 

and height difference.

Diameter

Liquid pipe

Gas pipe

3/8 in. (9.52 mm)

5/8 in. (15.88 mm)

2.  ABOUT THIS PRODUCT

2.1. Precautions for using R410A refrigerant

The basic installation work procedures are the same as conventional refrigerant 

(R22) models.

However, pay careful attention to the following points:

Since the working pressure is 1.6 times higher than that of conventional refrigerant 

(R22) models, some of the piping and installation and service tools are special. (See 

the following table.)

Especially, when replacing a conventional refrigerant (R22) model with a new refrigerant 

R410A model, always replace the conventional piping and flare nuts with the R410A piping 

and flare nuts.
Models that use refrigerant R410A have a different charging port thread diameter to pre-

vent erroneous charging with conventional refrigerant (R22) and for safety. Therefore, 

check beforehand. [The charging port thread diameter for R410A is 1/2-20 UNF.]
Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with 

refrigerant (R22) models. Also, when storing the piping ,securely seal the opening by 

pinching, taping, etc.
When charging the refrigerant, take into account the slight change in the composition of 

the gas and liquid phases. And always charge from the liquid phase where refrigerant 

composition is stable.

2.2. Special tools for R410A

Tool name

Contents of change

Gauge manifold

Pressure  is  high  and  cannot  be  measured  with  a  conven-

tional  (R22)  gauge. To  prevent  erroneous  mixing  of  other 

refrigerants, the diameter of each port has been changed.

It is recommended the gauge with seals -30 inHg to 768 psi 

(-0.1 to 5.3 MPa) for high pressure.

-30 inHg to 551 psi (-0.1 to 3.8 MPa) for low pressure.

Charge hose

To increase pressure resistance, the hose material and base 

size were changed.

Vacuum pump

A  conventional  vacuum  pump  can  be  used  by  installing  a 

vacuum pump adapter.

Gas leakage detector

Special gas leakage detector for HFC refrigerant R410A.

Copper pipes

It is necessary to use seamless copper pipes and it is desirable that the amount of residual 

oil is less than 0.004 oz/100 ft. (40 mg/10 m). Do not use copper pipes having a collapsed, 

deformed or discolored portion (especially on the interior surface). Otherwise, the expansion 

value or capillary tube may become blocked with contaminants.

As an air conditioner using R410A incurs pressure higher than when using R22, it is nec-

essary to choose adequate materials. 

 WARNING

Do not use the existing (for R22) piping and flare nuts.

If the existing materials are used, the pressure inside the refrigerant cycle will rise and 

cause failure, injury, etc. (Use the special R410A materials.)

When installing and relocating the air conditioner, do not mix gases other than the 

specified refrigerant (R410A) to enter the refrigerant cycle.

If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to 

an abnormally high value and cause failure, injury, etc.

2.3. For authorized service personnel only.

 WARNING

For the air conditioner to operate satisfactorily, install it as outlined in this installation 

manual.

Connect the indoor unit and outdoor unit or branch box with the air conditioner piping 

and cables available from your local distributor. This installation manual describes the 

correct connections using the installation set available from your local distributor.

Do not turn on the power until all installation work is complete.

 CAUTION

This installation manual describes how to install the indoor unit only. 

To install the outdoor unit or branch box, refer to the installation manual included with 

the outdoor unit or branch box.

•  Be careful not to scratch the air conditioner when handling it.

•  After installation, explain correct operation to the customer, using the operating manual.

9387082098-02_IM.indb   2

21/03/2016   10:12:49

Содержание ASU30RLE

Страница 1: ... a Ceiling or Wall Make sure the ceiling wall is strong enough to hold the unit s weight It may be necessary to construct a strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause drip ping and water damage to walls and floors In an Area with High Winds Securely anchor the outdoor unit down with bolts and a met...

Страница 2: ... erroneous charging with conventional refrigerant R22 and for safety Therefore check beforehand The charging port thread diameter for R410A is 1 2 20 UNF Be more careful that foreign matter oil water etc does not enter the piping than with refrigerant R22 models Also when storing the piping securely seal the opening by pinching taping etc When charging the refrigerant take into account the slight ...

Страница 3: ...nimals may urinate on the unit or ammonia may be generated Do not use the unit for special purposes such as storing food raising animals grow ing plants or preserving precision devices or art objects It can degrade the quality of the preserved or stored objects Do not install where there is the warning of combustible gas leakage Do not install the unit near a source of heat steam or flammable gas ...

Страница 4: ...ck Drain cap Removal method of drain hose Remove the screw at the left of drain hose and pull out drain hose Installation method of drain hose Vertically insert the drain hose toward the inside so that the drain fixture white can ac curately align with the screw hole around the drain cock After inserting and before replacing please reinstall and fix the removed screws Please hold around the joint ...

Страница 5: ...CAUTION Connect the piping so that the control box cover can easily be removed for servicing when necessary In order to prevent water from leaking into the control box make sure that the piping is well insulated When the flare nut is tightened properly by your hand hold the body side coupling with a wrench then tighten with a torque wrench See the table below for the flare nut tightening torques T...

Страница 6: ...e terminal screw tightening torques Tightening torque lbf in N m M4 screw 11 to 16 1 2 to 1 8 CAUTION Attach the cable clamp firmly by holding the connection cable and make sure that the clamp is fixed securely Incomplete attachment of the cable clamp might cause a malfunction of the open panel Match the terminal block numbers and connection cable colors with those of the outdoor unit Erroneous wi...

Страница 7: ...ation Vinyl tape Wrap with cloth tape Cloth tape Drain hose Connection cable Pipe Drain hose Drain hose Connection pipe Wall pipe Connection cable Left piping For connection from the left rear Pipe Connection pipe heat insulation Indoor unit pipe heat insulation Bind the pipes together so that there is no gap Seal A is used when the diam eter of gas pipe is Ø12 70 or more Butt connection pipe heat...

Страница 8: ...tricted When function setting is Operation Stop mode 2 Input signal Command OFF ON Operation ON OFF Stop R C disabled 10 1 2 External output A twisted pair cable 22AWG should be used Maximum length of cable is 25 m 82 ft Use an external input and output cable with appropriate external dimension depending on the number of cables to be installed Output voltage Hi DC12V 2V Lo 0V Permissible current 5...

Страница 9: ...re to insulate the connecting parts when extending the cable Server room control For server room control connect the communication cable to the terminal block following the same procedure as the remote controller cable For details refer to the service instruction for Server room control Note Wire colors may not match Match the numbers on the terminal block of each indoor unit Tab Cable clamper and...

Страница 10: ...ch indoor unit using the Function setting a 3 wire type Function setting RC AD setting Factory setting 00 When connecting multiple indoor units to 1 standard wired remote controller set the address at RC AD setting in sequence from 00 b 2 wire type Function setting RC AD setting Factory setting 00 Since the remote controller address settings are automatically configured you do not need to configur...

Страница 11: ... buttons to select the setting value Press the MIN HEAT button to switch between the left and right digits 4 Press the MODE button in the order listed to confirm the settings Please confirm that the beep sounds 5 Next please press START STOP button Please confirm that the beep sounds 6 Press the RESET button to cancel the function set ting mode 7 After completing the FUNCTION SETTING be sure to tu...

Страница 12: ...ot set first Room temperature control settings Function 30 31 92 93 will be reset and you must re do them again Heat Insulation condition building insulation Heat insulation conditions differ according to the installed environment Standard insulation 00 allows system to rapidly respond to the cooling or heating load changes High insulation 01 is when the heat insulation structure of the building i...

Страница 13: ...g to the customer in accordance with the operating manual 1 Starting and stopping method operation switching temperature adjustment timer air flow switching and other remote controller operations 2 Air filter removal and cleaning and how to use the air louvers 3 Give the operating manual to the customer 18 ERROR CODES If you use a wireless remote controller the lamp on the photo detector unit will...

Страница 14: ...sure sensor error Suction pressure sensor error High pressure switch error 9 4 Trip detection 9 5 Compressor rotor position detection error permanent stop 9 7 Outdoor unit fan motor 1 error 9 8 Outdoor unit fan motor 2 error 9 9 4 way valve error 9 10 Coil expansion valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes e...

Отзывы: