2. AUTO CHANGEOVER OPERATION
01-05
START
T
S
:
Setting temperature
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
NO
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
YES
YES
When the air conditioner is set to the AUTO mode by remote control, operation starts in the optimum
mode from among the Heating, Cooling, Dry and Monitoring modes.
During operation, the optimum mode is automatically switched in accordance with temperature changes.
The temperature can be set between 18°C and 30°C in 1°C steps.
NO
<Ts- 2°C ?
YES
YES
NO
NO
NO
NO
YES
YES
HEATING OPERATION
COOLING OPERATION
>Ts+2°C ?
Room temp.
Room temp.
When air conditioner is set to AUTO mode by remote control,
operation starts in the optimum mode from among heating,
cooling, dry and monitoring modes.
During operation, the optimum mode is automatically switched
in accordance with temperature changes.
Temperature can be set between 18°C and 30°C in 1°C steps.