4. OUTDOOR FAN CONTROL
01-10
1. OUTDOOR FAN MOTOR
2. FAN SPEED IN COOLING AND DRY OPERATION
In cooling and dry operation, fan speed is defined
by outdoor temperature and compressor frequency.
This outdoor unit has a DC fan motor.
(Control method is different between AC and DC motors.)
When fan motor starts to run,
it keeps 500 rpm for 20 seconds.
Fan motor
MFE-S60VB2F
Cooling
Z zone
Cool, Dry
F zone
Cool, Dry
G zone
Cool, Dry
Y zone
Fan
step
9
8
7
6
5
Dry
Outside air temperature zone selection
21°C
10°C
Outside air
temperature rises
Outside air
temperature drops
Z zone
Y zone
F zone
G zone
12°C
2°C
19°C
0°C
4
3
2
1
630 rpm
630 rpm
510 rpm
510 rpm
400 rpm
400 rpm
400 rpm
400 rpm
870 rpm
870 rpm
770 rpm
770 rpm
1,050 rpm
1,050 rpm
1,050 rpm
1,050 rpm
1,030 rpm
630 rpm
510 rpm
400 rpm
400 rpm
870 rpm
770 rpm
1,050 rpm
1,050 rpm
1,030 rpm
630 rpm
510 rpm
400 rpm
400 rpm
870 rpm
770 rpm
1,050 rpm
1,050 rpm
1,030 rpm
630 rpm
510 rpm
400 rpm
400 rpm
870 rpm
770 rpm
1,050 rpm
1,050 rpm
S-Hi1
Hi
-
1,050 rpm
-
1,050 rpm
-
-
-
-
-
-
1,030 rpm
1,030 rpm