3. SLEEP TIMER
When sleep is set, room temperature is monitored and operation is stopped automatically.
When operation mode or set temperature is changed after the sleep timer is set,
operation is continued according to the changed setting of the sleep timer from that time ON.
Set temperature rises
( Ts : Set temperature )
Stop of operation
Set temperature lowers
( Ts : Set temperature )
Ts
Stop of operation
In cooling operation
When sleep timer is set, the set temperature is increased 1°C.
It increases the setting temperature another 1°C after 1 hour.
After that, the set temperature is not changed and the operation
is stopped at the time of timer setting.
Ts
+1°C
+2°C
Set
60min
In heating operation
When the sleep timer is set, the set temperature is decreased 1°C.
It decreases the set temperature another 1°C every 30 minutes.
Upon lowering 4°C, the set temperature is not changed and the operation
stops at the time of timer setting.
-4°C
-3°C
-2°C
-1°C
Set
30min
30min
30min
01-15