42
Installation and operating manual “1350-EN”
Heat pump, Split, single service
6741
S
Temperature alarm initiation CC2
---, 10… 240 min
10 min
---
6745
S
DHW load alarm
---, 1… 48 h
1 h
---
6746
S
Temperature alarm initiation Cold 1
---, 10… 240 min
10 min
---
6800
S
History 1
Time, Date, Error code
6802
S
History 2
Time, Date, Error code
6804
S
History 3
Time, Date, Error code
6806
S
History 4
Time, Date, Error code
6808
S
History 5
Time, Date, Error code
6810
S
History 6
Time, Date, Error code
6812
S
History 7
Time, Date, Error code
6814
S
History 8
Time, Date, Error code
6816
S
History 9
Time, Date, Error code
6818
S
History 10
Time, Date, Error code
Maintenance / special regime
7070
I
Interval time for maintenance HP
--- , 1… 240
1 Month
---
7071
I
Operating time HP since last maintenance.
Reset ? (no, yes)
0… 240
1 Month
0
7072
I
Maximum number of starting of the compressor 1,
authorized per hour of operation.
--- , 0,1 … 12
0,1
---
7073
I
Average number of starts of the compressor per hour of
operation, since the 6 last weeks.
Reset ? (no, yes)
0 … 12
0
7076
I
Maximum discrepancy condens / week
--- , 1… 250
1
---
7077
I
Current maximum discrepancy condens / week
Reset ? (no, yes)
0… 250
7078
I
Minimum discrepancy condens / week
--- , 1… 250
1
---
7079
I
Current minimum discrepancy condens / week
Reset ? (no, yes)
0… 250
0
7090
I
DHW tank period
--- , 1… 240
1 Month
---
7091
I
DHW tank since maintenance
Reset ? (no, yes)
0… 240
0
7092
I
Heat pump DHW min load temperature
5… 80 °C
1
5 °C
7141
U
Emergency regime
Off, ON
Off
Off: The heat pump does not use the backup electrical heating system or the boiler connection when a fault occurs (error
370)
ON: The heat pump uses the backup electrical system or the boiler connection when a fault occurs (error 370).
In the "ON" position, the energy costs can be onerous if the error is not eliminated.
7142
S
Emergency service operating type
Manual, Automatic
Manual
Manual: Emergency mode is not active when a fault occurs. (Emergency mode = OFF)
Automatic: Emergency mode is active when a fault occurs. (Emergency mode = ON)
In automatic position, the energy cost can be onerous if the error is not detected and eliminated.
7150
I
Outside temperature simulation
--- , -50 … 50 °C
0,5
---
7181
I
Contact's telephone 1
0 … 255
7183
I
Contact's telephone 2
0 … 255
Line
Function
Setting range
or display
Setting
increment
Basic
setting