2.5
Installing the hydraulic module
2.5.1
Installation precautions
•
The room in which the appliance operates must
comply with the prevailing regulations.
•
To facilitate maintenance and to allow access to the
various components, we recommend that you
provide sufficient space all around the hydraulic
module (figure 15).
•
Be careful not to bring inflammable gas near to the
heat pump during its installation, in particular when
it requires brazing
The appliances are not fireproof and should not
therefore be installed in a potentially explosive
atmosphere.
2.5.2
Positioning the hydraulic module
-
1, 2, 3 : Remove the front panel (
2 screws A, figure 16
)
-
4, 5 : Remove the sides (4 screws B, figure 17).
-
Fix the support solidly (3 screws and plugs) to a flat,
hard-wearing wall (not a light partition) ensuring
that it is correctly levelled.
-
Hook the appliance onto its support.
-
Refit the sides.
-
Refit the front facing.
Installation and operating manual “1350-EN”
17
Heat pump, Split, single service
200 mm
1000 mm
150 mm
150 mm
Figure 15 - Minimum installation clearances
around the hydraulic module and distances to the
combustible partitions
1
3
2
A
Figure 16 - Removing the front facing
90 mm
(S)
505 mm
240 mm
150 mm
200 mm
305 mm
Figure 17 - Removing the sides and fixing the support (S)
B
B
(S)
5
5
4