8. COMPRESSOR CONTROL
1. OPEARTION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the table10.
Cooling
Heating
Min
Max
Min
Max
Min
Max
Dry
AOTG18KMTC
AOTG22KMTC
AOTG24KMTC
10rps
94rps
10rps
130rps
18rps
24rps
(Table10 : Compressor Operation Frequency Range)
2. OPEARTION FREQUENCY CONTROL AT START UP
The compressor frequency soon after the start-up is controlled as shown in the Fig.9.
(Fig.9 : Compressor Control at Start-up)
01-09
10rps
74rps
10rps
130rps
18rps
24rps
10rps
111rps
10rps
130rps
18rps
24rps
Time
Time
Time
Time
Time
(Frequency)
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Time
Time
Time
Time
Time
60sec
140sec
170sec
200sec
350sec
410sec
(Time)
Frequency
Time
6
Frequency
Time
6
35rps
52rps
64rps
71rps
89rps
97rps
AOTG18/ 22/ 24KMTC
AOTG18/ 22/ 24KMTC