15. MANUAL AUTO OPERATION (Indoor unit body operation)
If MANUAL AUTO Button is set, the operation is controlled as shown in Table13.
If the remote control is lost or battery power dissipated, this function will work without the remote control.
OPERATION MODE
Auto changeover
FAN CONT. MODE
Auto
TIMER MODE
Continuous
SETTING TEMP.
24°C
SETTING LOUVER
Standard
SWING
ECONOMY
OFF
OFF
(Table13)
(No timer setting available)
17. COMPRESSOR PREHEATING
01-13
Forced cooling operation
Cooling
16. FORCED COOLING OPERATION
Forced cooling operation is started when pressing MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation LED and timer LED blink during the forced cooling operation. They blink for 1 second ON
and 1 second OFF on both operation LED and timer LED (same as test operation).
Forced cooling operation is released after 60 minutes of starting operation.
The FORCED COOLING OPERATION will start as shown in Table13.
Hi
Horizontal
OFF
Room Temp is not controlled
Manual auto operation
-
-
18. 10°C HEAT OPERATION
The 10°C HEAT operation functions by pressing 10°C HEAT button on the remote controller.
The 10°C HEAT operation is almost the same operation as below settings.
Mode
Heating
Setting temperature 10°C
Fan mode
AUTO
( Table14 )
19. ECONOMY OPERATION
The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
Mode
Cooling/ Dry
Heating
Target temperature Setting temp.+1°C Setting temp.-1°C
( Table15 )
When the outdoor heat exchanger temperature is lower than 0°C and the outside air temp. is
more than 20°C and the all operation has been stopped for 30 minutes,
power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started and when the outdoor heat exchanger temperature rises to
2°C or greater, preheating is ended.