01-06
Switch the airflow [Auto] at cooling mode, and the indoor fan motor will run as shown in Fig.6.
7. MOISTURE RETURN PREVENTION CONTROL (Cooling mode& Dry mode)
When the defrost operation starts, the indoor fan runs according to cool air prevention control for 20 seconds.
And the fan is stopped if 20 seconds have passed.
When 60 seconds have passed after defrost operation is released,
the fan runs according to cool air prevention control
8. DEFROST OPERATION
( Fig.6 : Indoor Fan Control )
Compressor
ON
OFF
Indoor fan
Setting air flow
Indoor fan
(as shown in Table 5)
S-Lo
OFF
10
30
60
180
60
180
60
10
30
(SEC)
( Table5 : Indoor fan speed )
X zone
J zone
ASTG18KMTC
ASTG22KMTC
ASTG24KMTC
760rpm
760rpm
760rpm
670rpm
670rpm
670rpm
760rpm
760rpm
760rpm
Dry
Cooling
Содержание AOTG18KMTC
Страница 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION WALL MOUNTED type INVERTER ...
Страница 25: ...2 TROUBLE SHOOTING WALL MOUNTED type INVERTER ...
Страница 82: ...3 APPENDING DATA WALL MOUNTED type INVERTER ...