JP (Jumper) Setting
[Indoor Unit]
AS*9/12LSACW
AS*9/12LSBCW
AS*14/18LSBCW
Remote control custom code
When multiple number of indoor units are installed in the same room, erroneous receipt of the signal can
be avoided by setting up the remote control custom code separately.
To set up the remote control custom code, always set up the same code on both indoor unit PCB and
remote control PCB.
(When the indoor unit PCB is changed to Code B, it can not receive the signal unless remote control PCB
is also changed to Code B.)
Indoor Unit
Remote Control
JM1(JP)
D4 (Diode)
Code A (Default)
Code B
Auto Restart
It is possible to disengage Auto Restart function if it is not needed.
Indoor Unit
JM2 (JP)
With Auto Restart function
(Default)
YES
Without Auto Restart
function
NO
[Outdoor Unit]
AO*9/12LSAC
JP
JM101
JM102
JM103
JM104
JM105
JM106 JM107
Normal Preheat
NO
NO
NO
NO
NO
YES
NO
9LSAC
Higher Preheat
NO
NO
NO
YES
NO
NO
NO
Normal Preheat
NO
YES
NO
NO
NO
NO
NO
12LSAC
Higher Preheat
NO
NO
NO
NO
NO
NO
NO
AO*9/12LFBC
JP
JM500
Normal Preheat
YES
Higher Preheat
NO
AO*14/18LFBC
JP
JM101 JM102
JM103
JM104
JM105
JM106
JM107
Normal Preheat
NO
YES
NO
NO
NO
NO
NO
14LSBC
Higher Preheat
NO
NO
NO
NO
NO
NO
NO
Normal Preheat
NO
NO
NO
NO
NO
YES
NO
18LSBC
Higher Preheat
NO
NO
NO
YES
NO
NO
NO
- it is possible to select the higher or standard level of preheating function.
- When it is set up at the higher level of preheat, the magnetic noise of the compressor becomes higher.
08-01
AR-JE (LSAC)
X
X
D3 (Diode)
AR-NJ (LSBC)
X
*
*
Содержание AO*12LFBC
Страница 4: ...1 SPECIFICATIONS R410A WALL MOUNTED type INVERTER ...
Страница 8: ...2 DIMENSIONS R410A WALL MOUNTED type INVERTER ...
Страница 10: ...D I M E N S I O N S AS 12LSBCW AO 12LFBC Models AS 9LSBCW AO 9LFBC unit mm 275 2 000 215 790 02 02 ...
Страница 12: ...3 REFRIGERANT SYSTEM DIAGRAM R410A WALL MOUNTED type INVERTER ...
Страница 16: ...4 CIRCUIT DIAGRAM R410A WALL MOUNTED type INVERTER ...
Страница 20: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 40: ...6 REFRIGERANT CAUTION R410A R410A WALL MOUNTED type INVERTER ...
Страница 46: ......
Страница 47: ......
Страница 70: ...9 INSTALLATION MANUAL R410A WALL MOUNTED type INVERTER ...
Страница 83: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan GS17032005 March 2005 Printed in Japan ...