Be careful not to mix moisture and
contamination into the pipe
Moisture
and
contamination
in the pipe is a cause of
trouble.
Air purge
Always use a
vacuum pump
to purge air.
Refrigerant charge
Do it always from the
liquid
phase
side.
Don't charge from the
gas
phase side.
Compressor oil is changed
Be careful to handle synthetic oil, since it
resolves easily by moisture and contamination.
Don't mix new synthetic oil and mineral oil.
It may cause trouble.
We developed new synthetic oil, since HFC
refrigerant doesn't dissolve in mineral (for R22)oil.