15. MANUAL AUTO OPERATION (Indoor unit body operation)
If MANUAL AUTO Button is set, the operation is controlled as shown in Table 12.
If the remote control is lost or battery power dissipated, this function will work without the remote
control.
OPERATION MODE
Auto changeover
FAN CONT. MODE
Auto
TIMER MODE
Continuous
SETTING TEMP.
24 C
SETTING LOUVER
Standard
SWING
OFF
When the outdoor heat exchanger temperature is lower than temperature and the heating operation has
been stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started, and when the outdoor temperature rises to temperature or greater, preheating
is ended.
AS*9LSACW
AS*12LSACW
AS*9LSBCW
AS*12LSBCW
AS*14LSBCW
AS*18LSBCW
AS*9LSACW
900rpm
36Hz
AS*12LSACW
900rpm
36Hz
AS*9LSBCW
900rpm
36Hz
AS*12LSBCW
900rpm
36Hz
AS*14LSBCW
900rpm
24Hz
AS*18LSBCW
900rpm
24Hz
(Table 12)
(No timer setting available)
16. COMPRESSOR PREHEATING
(Table 13 : Preheating Operation / Release Temperature)
Temperature Temperature
5 C
5 C
5 C
5 C
5 C
5 C
7 C
7 C
7 C
7 C
7 C
7 C
17. COIL DRY OPERATION CONTROL
The coil-dry operation functions by pressing Coil Dry operation button on the remote controller.
The coil-dry operation is consisted of 3 cycles of [Fan operation 3 minutes / Heating operation
2 minutes], and Fan operates for 3 minutes at last before ending the air conditioner operation.
(It takes 18 minutes to complete the coil-dry operation.)
Following table indicates the indoor unit setting on the coil-dry operation.
(Table 14 : Coil-dry Operating Functions)
Indoor Fan Speed
Compressor
Frequency
Louver
Position
Main Unit
Indocation
Coil-dry indication : ON
Other indication : OFF
05-13
Содержание AO*12LFBC
Страница 4: ...1 SPECIFICATIONS R410A WALL MOUNTED type INVERTER ...
Страница 8: ...2 DIMENSIONS R410A WALL MOUNTED type INVERTER ...
Страница 10: ...D I M E N S I O N S AS 12LSBCW AO 12LFBC Models AS 9LSBCW AO 9LFBC unit mm 275 2 000 215 790 02 02 ...
Страница 12: ...3 REFRIGERANT SYSTEM DIAGRAM R410A WALL MOUNTED type INVERTER ...
Страница 16: ...4 CIRCUIT DIAGRAM R410A WALL MOUNTED type INVERTER ...
Страница 20: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 40: ...6 REFRIGERANT CAUTION R410A R410A WALL MOUNTED type INVERTER ...
Страница 46: ......
Страница 47: ......
Страница 70: ...9 INSTALLATION MANUAL R410A WALL MOUNTED type INVERTER ...
Страница 83: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan GS17032005 March 2005 Printed in Japan ...