1. COOLING OPERATION
1-1 COOLING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is 2 C higher than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is 2.5 C lower than a set temperature, the compressor will be
stopped.
* When the room temperature is b2 C to -2.5 C of the setting temperature,
the compressor frequency is controlled within the range shown in Table1.
However, the maximum frequency is limited in the range shown in Figure 1 based on the
fan speed mode and the outdoor temperature.
minimum
frequency
maximum
frequency
maximum
frequency
AS*9LSACW
18Hz
60Hz
80Hz
AS*12LSACW
18Hz
80Hz
96Hz
AS*9LSBCW
18Hz
61Hz
80Hz
AS*12LSBCW
18Hz
80Hz
96Hz
AS*14LSBCW
18Hz
70Hz
90Hz
AS*18LSBCW
18Hz
70Hz
90Hz
Outside air Outside air
temperature temperature
36 C
A zone
34 C
32 C
B zone
30 C
21 C
C zone
19 C
D zone
Hi
Me
Lo
Quiet
A zone
80Hz
51Hz
45Hz
33Hz
B zone
80Hz
51Hz
45Hz
33Hz
C zone
80Hz
51Hz
45Hz
33Hz
9LSACW
D zone
51Hz
39Hz
33Hz
27Hz
A zone
96Hz
60Hz
51Hz
33Hz
B zone
96Hz
60Hz
51Hz
33Hz
C zone
80Hz
60Hz
51Hz
33Hz
12LSACW
D zone
51Hz
42Hz
36Hz
27Hz
A zone
80Hz
61Hz
51Hz
33Hz
B zone
80Hz
61Hz
51Hz
33Hz
C zone
80Hz
61Hz
51Hz
33Hz
9LSBCW
D zone
51Hz
42Hz
36Hz
22Hz
A zone
96Hz
61Hz
51Hz
33Hz
B zone
96Hz
61Hz
51Hz
33Hz
C zone
96Hz
61Hz
51Hz
33Hz
12LSBCW
D zone
51Hz
42Hz
36Hz
22Hz
A zone
90Hz
45Hz
42Hz
30Hz
B zone
90Hz
45Hz
42Hz
30Hz
C zone
90Hz
45Hz
42Hz
30Hz
14LSBCW
D zone
49Hz
38Hz
34Hz
24Hz
A zone
90Hz
45Hz
42Hz
30Hz
B zone
90Hz
45Hz
42Hz
30Hz
C zone
90Hz
45Hz
42Hz
30Hz
18LSBCW
D zone
49Hz
38Hz
34Hz
24Hz
( Table 1 : Compressor Frequency Range )
( Fig. 1 : Limit of Maximum Frequency based on Outdoor Temperature )
When the compressor operates for 30 minutes continuously at over the maximum frequency ,
the maximum frequency is changed from Maximum Frequency to Maximum Frequency .
The room temperature is controlled 1 C lower than the setting temperature for 40 minutes
after starting the operation.
After 40 minutes, it is controlled based on the normal setting temperature.
05-01
Содержание AO*12LFBC
Страница 4: ...1 SPECIFICATIONS R410A WALL MOUNTED type INVERTER ...
Страница 8: ...2 DIMENSIONS R410A WALL MOUNTED type INVERTER ...
Страница 10: ...D I M E N S I O N S AS 12LSBCW AO 12LFBC Models AS 9LSBCW AO 9LFBC unit mm 275 2 000 215 790 02 02 ...
Страница 12: ...3 REFRIGERANT SYSTEM DIAGRAM R410A WALL MOUNTED type INVERTER ...
Страница 16: ...4 CIRCUIT DIAGRAM R410A WALL MOUNTED type INVERTER ...
Страница 20: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 40: ...6 REFRIGERANT CAUTION R410A R410A WALL MOUNTED type INVERTER ...
Страница 46: ......
Страница 47: ......
Страница 70: ...9 INSTALLATION MANUAL R410A WALL MOUNTED type INVERTER ...
Страница 83: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan GS17032005 March 2005 Printed in Japan ...