6. Capacity table
6-1. Combinations
¢
Model: AOU18RLXFZ
Cooling
1) Non-ducted
Combination of indoor unit
Rated capacity for each in-
door unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1
Room 2
Total
Room 1
Room 2
Room 1
Room 2
Min.
Rated
Max.
Min.
Rated
Max.
7
7
14
7.05
7.05
8.70
8.70
6.10
14.10
17.40
0.50
1.30
1.64
7
9
16
7.09
9.11
8.66
11.14
6.10
16.20
19.80
0.50
1.44
1.81
7
12
19
6.63
11.37
7.74
13.26
6.10
18.00
21.00
0.50
1.43
2.06
9
9
18
9.00
9.00
10.50
10.50
6.10
18.00
21.00
0.50
1.44
2.06
9
12
21
7.71
10.29
9.00
12.00
6.10
18.00
21.00
0.50
1.44
2.06
2) Ducted
Combination of indoor unit
Rated capacity for each in-
door unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1
Room 2
Total
Room 1
Room 2
Room 1
Room 2
Min.
Rated
Max.
Min.
Rated
Max.
7
9
16
7.09
9.11
8.66
11.14
6.10
16.20
19.80
0.50
1.49
1.86
7
12
19
6.63
11.37
7.74
13.26
6.10
18.00
21.00
0.50
1.48
2.11
9
9
18
9.00
9.00
10.50
10.50
6.10
18.00
21.00
0.50
1.49
2.14
9
12
21
7.71
10.29
9.00
12.00
6.10
18.00
21.00
0.50
1.49
2.14
NOTES:
Specifications are based on the following conditions.
• Power source of specifications: 230 V
• 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h
• 2 indoor units should be connected.
• Cooling: Indoor temperature of 80 °FDB (26.7 °CDB)/67 °FWB (19.4 °CWB), and outdoor tem-
perature of 95 °FDB (35 °CDB)/75 °FWB (23.9 °CWB).
• Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit—Indoor unit]
• The total ability of connected indoor units is from 14,000 Btu up to 21,000 Btu.
• Non-Ducted system combinations input are based on wall mount models. The input of combina-
tions including cassette models may be a little higher.
• Ducted system combinations capacities are based on slim duct units excepting 7,000-Btu mod-
els. 7,000 Btu models are based on wall mount models.
- 183 -
6-1. Combinations
6. Capacity table
OUTDOOR UNIT
AOU18RLXFZ
OUTDOOR UNIT
AOU18RLXFZ
Содержание AGU12RLF
Страница 8: ......
Страница 183: ...Part 2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AOU18RLXFZ ...
Страница 213: ...Part 3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AOU24RLXFZ ...
Страница 255: ...Part 4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AOU36RLXFZ1 ...