Indoor units: 7,000 Btu + 7,000 Btu
Indoor temperature
°FDB
60
65
70
75
78
Outdoor temperature
°FDB
°FWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
5
3
13.01
1.82
12.60
1.88
12.18
1.93
11.75
1.99
11.49
2.02
14
12
14.68
1.94
14.22
1.99
13.74
2.05
13.26
2.11
12.97
2.14
23
19
16.52
1.90
16.00
1.95
15.46
2.01
14.92
2.07
14.59
2.10
32
28
18.62
1.84
18.04
1.90
17.43
1.95
16.82
2.01
16.45
2.04
41
37
20.74
1.79
20.09
1.84
19.41
1.89
18.73
1.95
18.32
1.98
47
43
22.12
1.86
21.42
1.91
20.70
1.97
19.98
2.03
19.54
2.06
50
47
22.29
1.88
21.58
1.93
20.85
1.99
20.12
2.05
19.68
2.08
59
50
22.51
1.90
21.80
1.95
21.06
2.01
20.32
2.07
19.88
2.10
68
59
22.07
1.66
21.37
1.71
20.65
1.76
19.93
1.80
19.49
1.83
75
65
20.19
1.11
19.55
1.14
18.89
1.17
18.23
1.20
17.83
1.22
Indoor temperature
°CDB
15.6
18.3
21.2
23.9
25.6
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15.0
-16.1
3.81
1.82
3.69
1.88
3.57
1.93
3.44
1.99
3.37
2.02
-10.0
-11.1
4.30
1.94
4.17
1.99
4.03
2.05
3.89
2.11
3.80
2.14
-5.0
-7.2
4.84
1.90
4.69
1.95
4.53
2.01
4.37
2.07
4.28
2.10
0.0
-2.2
5.46
1.84
5.29
1.90
5.11
1.95
4.93
2.01
4.82
2.04
5.0
2.8
6.08
1.79
5.89
1.84
5.69
1.89
5.49
1.95
5.37
1.98
8.3
6.1
6.48
1.86
6.28
1.91
6.07
1.97
5.85
2.03
5.73
2.06
10.0
8.3
6.53
1.88
6.33
1.93
6.11
1.99
5.90
2.05
5.77
2.08
15.0
10.0
6.60
1.90
6.39
1.95
6.17
2.01
5.96
2.07
5.83
2.10
20.0
15.0
6.47
1.66
6.26
1.71
6.05
1.76
5.84
1.80
5.71
1.83
23.9
18.3
5.92
1.11
5.73
1.14
5.54
1.17
5.34
1.20
5.22
1.22
Indoor units: 7,000 Btu + 9,000 Btu
Indoor temperature
°FDB
60
65
70
75
78
Outdoor temperature
°FDB
°FWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
5
3
13.25
1.77
12.84
1.82
12.40
1.88
11.97
1.93
11.70
1.96
14
12
15.05
1.79
14.58
1.84
14.09
1.89
13.59
1.94
13.29
1.98
23
19
16.93
1.79
16.39
1.84
15.84
1.89
15.28
1.94
14.95
1.98
32
28
19.38
1.77
18.77
1.82
18.13
1.87
17.50
1.92
17.11
1.95
41
37
21.95
1.74
21.25
1.79
20.53
1.84
19.82
1.90
19.38
1.93
47
43
23.41
1.81
22.67
1.87
21.90
1.92
21.13
1.97
20.67
2.01
50
47
23.58
1.79
22.84
1.84
22.06
1.89
21.29
1.94
20.82
1.98
59
50
23.81
1.79
23.06
1.84
22.28
1.89
21.50
1.94
21.03
1.98
68
59
23.35
1.62
22.61
1.66
21.84
1.71
21.08
1.76
20.62
1.79
75
65
23.64
1.08
22.89
1.11
22.12
1.14
21.34
1.17
20.87
1.19
Indoor temperature
°CDB
15.6
18.3
21.2
23.9
25.6
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15.0
-16.1
3.88
1.77
3.76
1.82
3.63
1.88
3.51
1.93
3.43
1.96
-10.0
-11.1
4.41
1.79
4.27
1.84
4.13
1.89
3.98
1.94
3.90
1.98
-5.0
-7.2
4.96
1.79
4.80
1.84
4.64
1.89
4.48
1.94
4.38
1.98
0.0
-2.2
5.68
1.77
5.50
1.82
5.31
1.87
5.13
1.92
5.02
1.95
5.0
2.8
6.43
1.74
6.23
1.79
6.02
1.84
5.81
1.90
5.68
1.93
8.3
6.1
6.86
1.81
6.64
1.87
6.42
1.92
6.19
1.97
6.06
2.01
10.0
8.3
6.91
1.79
6.69
1.84
6.47
1.89
6.24
1.94
6.10
1.98
15.0
10.0
6.98
1.79
6.76
1.84
6.53
1.89
6.30
1.94
6.16
1.98
20.0
15.0
6.84
1.62
6.63
1.66
6.40
1.71
6.18
1.76
6.04
1.79
23.9
18.3
6.93
1.08
6.71
1.11
6.48
1.14
6.26
1.17
6.12
1.19
- 192 -
6-3. Heating capacity
6. Capacity table
OUTDOOR UNIT
AOU18RLXFZ
OUTDOOR UNIT
AOU18RLXFZ
Содержание AGU12RLF
Страница 8: ......
Страница 183: ...Part 2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AOU18RLXFZ ...
Страница 213: ...Part 3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AOU24RLXFZ ...
Страница 255: ...Part 4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AOU36RLXFZ1 ...