How to use the adapter (optional part K9FZ1818)
UNIT D
UNIT C
UNIT B
UNIT A
Indoor unit B
(18,000 Btu)
Indoor unit A
(18,000 Btu)
Exchange liquid pipe size Ø1/4 in (Ø6.35 mm) for
Ø3/8 in (Ø9.52 mm) with an adapter kit.
These ports are not use.
Gas pipe of unit A is not exchanged.
Exchange liquid pipe size Ø1/4 in (Ø6.35 mm) for
Ø3/8 in (Ø9.52 mm) with an adapter kit.
Exchange gas pipe size Ø3/8 in (Ø9.52 mm) for
Ø1/2 in (Ø12.70 mm) with an adapter kit.
Outdoor unit
¢
Connection pipe length
Max.
Total
ft (m)
131 (40)
Each unit
82 (25)
Min.
Total
49 (15)
Each unit
25 (7.5)
¢
Refrigerant charge
Pipe length
(Total)
ft
65 or less
98
131 (Max.)
0.27 oz/ft
25 g/m
m
20 or less
30
40 (Max.)
Additional
charge
lb oz
0
8.9 oz
1 lb 1.8 oz
g
0
250
500