Indoor units: 7,000 Btu + 7,000 Btu + 7,000 Btu + 9,000 Btu
Indoor temperature
°FDB
60
65
70
75
78
Outdoor temperature
°FDB
°FWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
5
3
23.95
3.25
23.38
3.32
22.81
3.39
22.24
3.46
21.67
3.53
14
12
29.15
3.30
28.45
3.37
27.76
3.44
27.06
3.51
26.37
3.58
23
19
33.64
3.35
32.84
3.42
32.04
3.49
31.24
3.56
30.44
3.63
32
28
35.77
3.16
34.92
3.22
34.07
3.29
33.22
3.35
32.36
3.42
41
37
37.49
3.12
36.60
3.19
35.71
3.25
34.82
3.32
33.92
3.38
47
43
39.59
3.28
38.64
3.35
37.70
3.42
36.76
3.49
35.82
3.56
50
47
40.23
3.27
39.27
3.34
38.32
3.41
37.36
3.48
36.40
3.55
59
50
42.17
3.24
41.17
3.31
40.16
3.38
39.16
3.44
38.15
3.51
68
59
42.87
2.80
41.85
2.85
40.83
2.91
39.81
2.97
38.79
3.03
75
65
45.26
2.78
44.18
2.84
43.11
2.90
42.03
2.96
40.95
3.02
Indoor temperature
°CDB
15.6
18.3
21.2
23.9
25.6
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15.0
-16.1
7.02
3.25
6.85
3.32
6.68
3.39
6.52
3.46
6.35
3.53
-10.0
-11.1
8.54
3.30
8.34
3.37
8.14
3.44
7.93
3.51
7.73
3.58
-5.0
-7.2
9.86
3.35
9.62
3.42
9.39
3.49
9.15
3.56
8.92
3.63
0.0
-2.2
10.48
3.16
10.23
3.22
9.98
3.29
9.74
3.35
9.49
3.42
5.0
2.8
10.99
3.12
10.73
3.19
10.47
3.25
10.20
3.32
9.94
3.38
8.3
6.1
11.60
3.28
11.33
3.35
11.05
3.42
10.77
3.49
10.50
3.56
10.0
8.3
11.79
3.27
11.51
3.34
11.23
3.41
10.95
3.48
10.67
3.55
15.0
10.0
12.36
3.24
12.07
3.31
11.77
3.38
11.48
3.44
11.18
3.51
20.0
15.0
12.57
2.80
12.27
2.85
11.97
2.91
11.67
2.97
11.37
3.03
23.9
18.3
13.27
2.78
12.95
2.84
12.63
2.90
12.32
2.96
12.00
3.02
Indoor units: 7,000 Btu + 7,000 Btu + 7,000 Btu + 12,000 Btu
Indoor temperature
°FDB
60
65
70
75
78
Outdoor temperature
°FDB
°FWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
5
3
25.34
3.48
24.74
3.56
24.14
3.63
23.53
3.70
22.93
3.77
14
12
30.85
3.53
30.11
3.61
29.38
3.68
28.64
3.75
27.91
3.83
23
19
35.60
3.58
34.76
3.66
33.91
3.73
33.06
3.81
32.21
3.88
32
28
37.86
3.38
36.96
3.45
36.06
3.52
35.16
3.59
34.25
3.66
41
37
39.68
3.34
38.74
3.41
37.79
3.48
36.85
3.55
35.90
3.62
47
43
41.90
3.51
40.90
3.59
39.90
3.66
38.90
3.73
37.91
3.81
50
47
42.58
3.50
41.57
3.58
40.55
3.65
39.54
3.72
38.52
3.79
59
50
44.63
3.47
43.57
3.54
42.51
3.61
41.44
3.69
40.38
3.76
68
59
45.37
2.99
44.29
3.05
43.21
3.12
42.13
3.18
41.05
3.24
75
65
47.90
2.98
46.76
3.04
45.62
3.10
44.48
3.16
43.34
3.23
Indoor temperature
°CDB
15.6
18.3
21.2
23.9
25.6
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15.0
-16.1
7.43
3.48
7.25
3.56
7.07
3.63
6.90
3.70
6.72
3.77
-10.0
-11.1
9.04
3.53
8.83
3.61
8.61
3.68
8.39
3.75
8.18
3.83
-5.0
-7.2
10.43
3.58
10.19
3.66
9.94
3.73
9.69
3.81
9.44
3.88
0.0
-2.2
11.10
3.38
10.83
3.45
10.57
3.52
10.30
3.59
10.04
3.66
5.0
2.8
11.63
3.34
11.35
3.41
11.08
3.48
10.80
3.55
10.52
3.62
8.3
6.1
12.28
3.51
11.99
3.59
11.69
3.66
11.40
3.73
11.11
3.81
10.0
8.3
12.48
3.50
12.18
3.58
11.89
3.65
11.59
3.72
11.29
3.79
15.0
10.0
13.08
3.47
12.77
3.54
12.46
3.61
12.15
3.69
11.84
3.76
20.0
15.0
13.30
2.99
12.98
3.05
12.67
3.12
12.35
3.18
12.03
3.24
23.9
18.3
14.04
2.98
13.71
3.04
13.37
3.10
13.04
3.16
12.70
3.23
- 292 -
6-3. Heating capacity
6. Capacity table
OUTDOOR UNIT
AOU36RLXFZ1
OUTDOOR UNIT
AOU36RLXFZ1
Содержание AGU12RLF
Страница 8: ......
Страница 183: ...Part 2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AOU18RLXFZ ...
Страница 213: ...Part 3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AOU24RLXFZ ...
Страница 255: ...Part 4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AOU36RLXFZ1 ...