2) Ducted
Combination of indoor unit
Rated capacity for each indoor unit
(kBtu/h)
Maximum capacity for each indoor
unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1 Room 2 Room 3 Room 4
Total
Room 1 Room 2 Room 3 Room 4 Room 1 Room 2 Room 3 Room 4
Min.
Rated
Max.
Min.
Rated
Max.
18
18
-
-
36*1
16.70
16.70
-
-
18.00
18.00
-
-
11.00
33.40
36.00
0.94
3.89
4.36
7
7
18
-
32
7.00
7.00
18.00
-
7.90
7.90
19.60
-
11.00
32.00
35.40
0.98
3.72
4.28
7
7
24
-
38
6.50
6.50
22.20
-
6.80
6.80
23.40
-
11.00
35.20
37.00
0.98
4.10
4.48
7
9
12
-
28
7.00
9.00
12.00
-
8.00
10.20
13.50
-
11.00
28.00
31.70
0.98
3.27
3.85
7
9
18
-
34
6.90
8.80
17.80
-
7.50
9.80
19.10
-
11.00
33.50
36.40
0.98
3.90
4.41
7
12
12
-
31
7.00
12.00
12.00
-
8.00
13.50
13.50
-
11.00
31.00
35.00
0.98
3.61
4.24
7
12
18
-
37
6.70
11.40
17.10
-
7.00
12.00
18.00
-
11.00
35.20
37.00
0.98
4.10
4.48
9
9
9
-
27
9.00
9.00
9.00
-
10.20
10.20
10.20
-
11.00
27.00
30.60
0.98
3.14
3.70
9
9
12
-
30
9.00
9.00
12.00
-
10.20
10.20
13.50
-
11.00
30.00
33.90
0.98
3.49
4.10
9
9
18
-
36
8.80
8.80
17.60
-
9.20
9.20
18.60
-
11.00
35.20
37.00
0.98
4.10
4.48
9
12
12
-
33
8.80
11.80
11.80
-
9.90
13.10
13.10
-
11.00
32.40
36.10
0.98
3.77
4.37
9
12
18
-
39
8.20
10.80
16.20
-
8.50
11.40
17.10
-
11.00
35.20
37.00
0.98
4.10
4.48
12
12
12
-
36
11.70
11.70
11.80
-
12.30
12.30
12.30
-
11.00
35.20
36.90
0.98
4.10
4.47
7
7
7
7
28
7.00
7.00
7.00
7.00
8.00
8.00
8.00
8.00
11.00
28.00
32.00
1.17
3.10
3.64
7
7
7
9
30
7.00
7.00
7.00
9.00
8.00
8.00
8.00
10.20
11.00
30.00
34.20
1.17
3.32
3.90
7
7
7
12
33
6.90
6.90
6.90
11.80
7.70
7.70
7.70
13.00
11.00
32.50
36.10
1.17
3.60
4.16
7
7
7
18
39
6.30
6.30
6.30
16.30
6.80
6.80
6.80
17.60
11.00
35.20
38.00
1.17
3.90
4.38
7
7
9
9
32
7.00
7.00
9.00
9.00
7.80
7.80
10.00
10.00
11.00
32.00
35.60
1.17
3.55
4.03
7
7
9
12
35
6.90
6.90
8.90
11.80
7.50
7.50
9.70
12.90
11.00
34.50
37.60
1.17
3.82
4.33
7
7
12
12
38
6.50
6.50
11.10
11.10
7.00
7.00
12.00
12.00
11.00
35.20
38.00
1.17
3.90
4.38
7
9
9
9
34
6.90
8.90
8.90
8.90
7.70
9.90
9.90
9.90
11.00
33.60
37.40
1.17
3.72
4.31
7
9
9
12
37
6.70
8.60
8.60
11.30
7.20
9.20
9.20
12.40
11.00
35.20
38.00
1.17
3.90
4.38
9
9
9
9
36
8.80
8.80
8.80
8.80
9.50
9.50
9.50
9.50
11.00
35.20
38.00
1.17
3.90
4.38
9
9
9
12
39
8.12
8.12
8.12
10.84
8.77
8.77
8.77
11.69
11.00
35.20
38.00
1.17
3.90
4.38
NOTES:
• *
1
: Optional kit K9FZ1818 (UTP-MU36A2) shall be necessary for the dual zone system “18
+ 18”.
• *
2
: Wall mounted 18 type cannot be connected in this combination.
• Specifications are based on the following conditions.
– Power source of specifications: 230 V
– 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h, 15: 14,000 Btu/h, 18: 18,000 Btu/h, 24:
24,000 Btu/h
– 3 or more indoor units should be connected. (Only the combinations of the “18 + 18” can be
connected by using the optional kit K9FZ1818 (UTP-MU36A2).)
– Cooling: Indoor temperature of 80 °FDB (26.7 °CDB)/67 °FWB (19.4 °CWB), and outdoor
temperature of 95 °FDB (35 °CDB)/75 °FWB (23.9 °CWB).
– Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit—Indoor unit]
– The total ability of connected indoor units is from 27,000 Btu up to 39,000 Btu.
– Non-Ducted system combinations input are based on wall mount models. The input of combi-
nations including cassette models may be a little higher.
– Ducted system combinations capacities are based on slim duct units excepting 7,000-Btu
models. 7,000 Btu models are based on wall mount models.
- 256 -
6-1. Combinations
6. Capacity table
OUTDOOR UNIT
AOU36RLXFZ1
OUTDOOR UNIT
AOU36RLXFZ1