18
Basic Operation
7.
Fiber Cleaving
(1) To unlock the anvil lever, press the cleaver lid down gently. Next, slide the stopper
to the unlock position to open the cleaver lid. Then slide the upper clamp stopper.
(2)
Set the stripped optical fiber on the cleaver.
Verify the proper cleave length.
(3) Press down the anvil lever slowly until the cleave blade scratches the fiber.
(4) Press down the anvil lever quickly like striking when the anvil cleaves the fiber.
(5) Slowly release the pressure on the anvil lever . A spring force will bring it to its
open position.
(6) Remove and discard fiber fragments and put into a proper disposal container.
(7) Attach the fiber clamp cover to the upper fiber clamps.
(8) Press the anvil lever down, until the stopper can slide into place to lock the anvil
lever.
• Proper operation of the anvil lever can be seen at URL