76
Error Message List
Error
Code
Error
Message
Reason Solution
• The fiber is set too far
back and does not
reach the splice point.
• Press
RESET
, re-position the
fiber again with the end-face
closer to the electrodes.
01
ZL Motor
Overrun
(Forward)
• The fiber is not set
correctly at the bottom
of the V-groove. The
fiber is not located in
the Camera’s field of
view.
• Press
RESET
, and set the fiber
again to seat it correctly at the
bottom of the V-groove.
11
ZR Motor
Overrun
(Forward)
• The cleave length (bare
fiber part) is too short.
• Confirm the setting position of the
stripped fiber end on the fiber
cleaver. Check the cleave length.
02
ZL Motor
Overrun
(Backward)
The taper speed or taper
time is set too high.
Adjust the taper parameters in the
splice mode.
12
ZR Motor
Overrun
(Backward)
Only occurs in manual motor operation.
21
X motor
Overrun
(Forward)
22
X motor
Overrun
(Backward)
31
Y Motor
Overrun
(Forward)
04
32
Y Motor
Overrun
(Backward)
The fiber is not set
correctly at the bottom
of the V-groove. The
fiber is offset too far and
it exceeds the X or Y
motor range.
Press
RESET
and re-position the
fiber again to seat it correctly at the
bottom of the V-groove.
Содержание FSM-50S