38
Splice Menu
1-3.
Referring or editing splice mode
Splicing parameters in each splice mode
can be modified. Arc power and Arc time
are considered the two most vital
parameters. To edit parameters do the
following:
(1) In [Select Splice Mode] menu,
move cursor to a splice mode to be
modified. Press button to display
[Edit Splice Mode] menu.
(2) Move cursor by pressing
buttons to a parameter to be changed.
(3) Press to select parameter.
Press
to change its values.
Press to accept changed values.
Below is a figure showing the Arc discharge conditions (relationship between "Arc
power" and "Motor motion"). The conditions can be edited by changing the splicing
parameters listed below. Depending on splice mode, certain parameters cannot be
changed.
A: Prefuse Power,
B: Arc1 Power,
C: Arc2 Power,
D: Cleaning Arc,
E: Prefuse Time,
F: Forward Time related to Overlap,
G: Arc1 Time,
H: Arc2 ON Time,
I: Arc2 OFF Time,
J: Arc2 Time,
K: Taper Wait Time,
L: Taper Time related to Taper Length,
M: Taper Speed,
N: Rearc Time
Arc
discharge
Motor
move
F
D E
G
J
H
I
C
N
A
B
L
K
M
Select Splice Mode Menu
Edit Splice Mode Menu