19
Basic Operation
8.
Loading fiber to splicer
(1) Open wind protector and sheath
clamps.
(2) Place prepared fiber onto v-groove
so that the fiber tip is located
between the v-groove edge and tip
of electrode.
(
3) Hold fiber with fingers and close
sheath clamp so that the fiber does not
move. Make sure the fiber is placed in
the bottom of the v-grooves. If fiber is
not placed properly, reload fiber.
(4) Load another fiber in the same
manner as in step (3) above.
(5) Close wind protector.
• If fiber coating has some memory curl, place fiber so that the curve of
memory is turned upwards.
• Be careful to not bump the prepared fiber tips into anything to maintain
fiber end-face quality.
Fiber
Sheath clamp
Electrode