3. Technical data
3.1 400 V series
Output ratings
Type: FRN□□□ LM1S-4□
4.0
5.5
7.5
11
15
18.5
22
30
37
45
Rated voltage (V)
3-phase 380 to 480 V (Output voltage cannot be higher than input voltage)
Rated frequency (Hz)
50-60 Hz
Rated capacity at 440V (kVA)
6.8
10.2
14
18
24
29
34
45
57
69
Typical Motor capacity (kW)
4
5.5
7.5
11
15
18.5
22
30
37
45
Rated current (A)
*1
9
13.5
18.5
24.5
32
39
45
60
75
91
Overload current rating (A)
18 for 3 s
27 for 10 s
37 for 10 s
49 for 10 s
64 for 10 s
78 for 10 s
90 for 10 s
108 for 5 s
135 for 5 s
163 for 5 s
Overload capability (%)
200% for 3 s
200% for 10 s
180% for 5 s
Input values
Mains supply
3-phase 380 to 480 V; 50/60 Hz; Voltage: -15% to +10%; Frequency: -5% to +5%
External control supply
1-phase 200 to 480 V; 50/60Hz
1-phase 380 to 480V;
50/60 Hz
Input current with DC reactor (A)
7.5
10.6
14.4
21.1
28.8
35.5
42.2
57
68.5
83.2
Input current without DC reactor (A)
13
17.3
23.2
33
43.8
52.3
60.6
77.9
94.3
114
Required power supply capacity
(kVA)
5.2
7.4
10
15
20
25
30
40
48
58
Input values for battery operation
Battery operation voltage
48 VDC or higher
Auxiliary control power supply
1-phase 200 to 480 V; 50/60 Hz
1-phase 380 to 480 V;
50/60 Hz
Voltage/frequency variations
Voltage: -15% to +10% (Voltage unbalance: 2% or less); Frequency: -5% to +5%
Braking resistor values
Maximum braking time (s)
60
Duty cycle (%ED)
50
Minimum resistor value ± 5%
(Ω)
96
48
48
24
24
16
16
10
10
8
Options and Standards
DC reactor (DCRE)
Optional
EMC
– Filter
Optional
Safety standards
EN 61800-5-1, EN 61800-5-2 (SIL 2), EN ISO 13849-1 (Cat. 3, PL d)
EN61800-5-1
Protection degree (IEC60529)
IP20
IP00
Cooling
Fan cooling
Mass (kg)
2.8
5.6
5.7
7.5
11.1
11.2
11.7
24.0
33.0
34.0
*1
For 10 kHz Switching frequency, 45 °C ambient temperature and 80%ED