8. Keypad operation
7. ALM CAUSE (ALARM CAUSE)
In this menu the possible alarm causes are shown. After the selection of an alarm by pressing
key a possible causes of this alarm is shown.
8. DATA COPY
With this menu complete inverter function set up can be transferred from one inverter to another. This
may be helpful to set up different installations with the same motor and same characteristics. Be aware
that function protection (F00) is no copied. Motor data and communication set are copied only between
inverters of same range.
9. LOAD FCTR (LOAD FACTOR)
In this menu the maximum current, the average current and the average braking torque during a preset
measuring time can be measured in the real application.
8.3 Example of function setting
Figure 19: LCD display of the first 4 menus after
pressing
key
Figure 20: Menu selection (in this figure
maintenance menu is selected)
Figure 21: Selection of Menu 1
Figure 22: Function code selection. In this figure
P03 Rated current
from the P Group (Motor
functions)
Figure 23: To edit (go inside) the function
Figure 24: Changing the value of P03 (motor rated
current), in this example to 12.
After changing the value using the arrow keys, it can be saved by pressing key.
Cancellation without saving is possible by pressing key.
00,00
P01 M-POLES
P02 M-CAP
P03 M-Ir
P04 M-TUN
00,00
1. DATA SET
2. DATA CHECK
3. OPR MNTR
4. I/O CHECK
00,00
1.DATA SET
2.DATA CHECK
3.OPR MNTR
4.I/O CHECK
00,00
P03 M-Ir
12 A
0.00~500.00
00,00
2. DATA CHECK
3. OPR MNTR
4. I/O CHECK
5. MAINTENANC
00,00
P03 M-Ir
12 A
0.00~500.00
Actual value
Setting range