Page
7
of
42
Fuji Electric Europe GmbH
1. Safety information
• Do not turn the main circuit power (circuit breaker) ON or OFF in order to start or stop inverter operation.
Doing so could cause failure.
• Do not touch the heat sink and braking resistor because they become very hot.
Doing so could cause burns.
• Before setting the speeds (frequency) of the inverter, check the specifications of the machinery.
• The brake function of the inverter does not provide mechanical holding means.
Injuries could occur.
Maintenance and inspection, and parts replacement
• Turn the power OFF and wait for at least five minutes before starting inspection. Further, check that the LED
monitor is unlit and that the DC link bus voltage between the P (+) and N (-) terminals is lower than 25 VDC.
Otherwise, electric shock could occur.
• Maintenance, inspection, and parts replacement should be made only by qualified persons.
• Take off the watch, rings and other metallic objects before starting work.
• Use insulated tools.
Otherwise, electric shock or injuries could occur.
Disposal
• Treat the inverter as an industrial waste when disposing of it.
Otherwise injuries could occur.
Others
• Never attempt to modify the inverter.
Doing so could cause electric shock or injuries.
2. Conformity to European standards
The CE marking on Fuji Electric products indicates that they comply with the essential requirements of the Electromagnetic
Compatibility (EMC) Directive 2004/108/EC issued by the Council of the European Communities and the Low Voltage Directive
2006/95/EC.
Inverters with built-in EMC filter that bear a CE marking are in conformity with EMC directives. Inverters having no built-in EMC
filter can be in conformity with EMC directives if an optional EMC compliant filter is connected to them.
General purpose inverters are subject to the regulations set forth by the Low Voltage Directive in the EU. Fuji Electric declares the
inverters bearing a CE marking are compliant with the Low Voltage Directive.
FRENIC-Lift inverters are in accordance with the regulations of following council directives and their amendments:
EMC Directive 2004/108/EC (Electromagnetic Compatibility)
Low Voltage Directive 2006/95/EC (LVD)
For assessment of conformity the following relevant standards have been taken into consideration:
EN61800-3:2004
EN61800-5-1:2003
The FRENIC-Lift inverters are categorized as category C2 according to EN61800-3:2004. When you use these
products in the domestic environment, you may need to take appropriate countermeasures to reduce or eliminate
any noise emitted from these products.