2.2.8 Connecting optical fiber cable
・
The cable may be pinched by the surface cover. To protect the cable, it is required to attach a fixing jig to guide the
route or spiral tube around the cable.
・
If the plastic optical fiber is bent with curvature of 35 mm or less for a long period of time, the inter- dynamic breaking
unit communications link error may occur to generate an alarm. Keep the curvature 35 mm or more.
・
The plastic optical fiber allows a strong light (e.g., flashlight) to pass. A strong light may cause the inter- dynamic
breaking unit communications link error to generate an alarm.
Use the supplied optical fiber cable to connect the dynamic breaking unit and the high-speed serial communication- capable
terminal block. Note that the colors of the plugs at the ends of the cable are different; light gray and dark gray. Be sure to
match the colors of the plug and connector when connecting them. Connect the dynamic breaking units in a daisy-chain
method.
R-2528 T-1528
Dark gray
(reception)
Light gray
(transmission)
Dark gray
(reception)
Light gray
(transmission)
R-2528 T-1528
Dark gray
(reception)
Light gray
(transmission)
Dark gray
(reception)
Light gray
(transmission)
Figure 2.2-12 Connecting optical fiber cable