Configure Hall and VR sensors for frequency input
Hall: Use the red wire for signal reference and the white wire must
be disconnected. In this case, it is necessary to feed the sensor with
positive and negative
VR: Use the white wire for signal reference and the red wire for sensor
power
Configure Frequency Inputs
g - In the “
Frequency Inputs
” tab it is possible to configure 4 channels
for reading speed or RPM, but each kind of input requires additional
configurations
For example:
To configure the turbo RPM it is necessary to inform
the number of blades and divisions in the turbocharger so that the
reading is correct.
h - After configuring the channels, it is necessary to save the information
in the FT Input Expander by clicking on the “
Write Expander
” button.
i - After writing the channels to the FT Input Expander, it is necessary
to enable them in the CAN network, just click on the “
Yes”
button on
the message and the FTManager will update the map automatically.
If you click “
No
”, the association will be manual.