The CAN network allows the ECU to access the FT Input Expander’s channels. In addition, data reading is fully integrated through the FT
Manager software.
CAN Network Connection
The FT Input Expander harness has 2 exclusive connectors for the CAN network connection with other FuelTech products.
1 - Female Connector
2 - Male Connector
3 - Terminator
Plug the male connector (2) into the female connector of the ECU. In case you have more than one equipment connected to the CAN
network, it is necessary to remove such equipment’s CAN terminator and plug the Input Expander’s male connector (2) into this equipment’s
female connector.
The terminator (3) must always be installed in the female connector of the last equipment connected to the CAN network, this reduces
possible noise levels captured by the CAN network.
The male connector (1) must NOT be plugged into the female connector (2) of the same Harness. If this is done, the FT Input Expander
CAN Network will not work.