700-DTS-12 Rev. 28 - 16 Apr 2020
Page 6/28
connection can be unplugged. If applying dielectric grease, ensure that it is kept out of contact with
the electrical prongs and receptacles to avoid a poor electrical connection.
One of the male prongs on the DTS-12 end cap has a larger diameter than the other two. This larger
diameter prong must be aligned with the two reference nipples on the cable connector (as shown in
the connection photos) to ensure that the prongs are inserted into the correct receptacles. Forcing
insertion into the wrong position will permanently damage the connection. Aggressive twisting can
also result in bending and breaking prongs.
DO:
•
Use clean dielectric grease to lubricate the
DTS-12 End Cap
•
Keep prongs and receptacles free from
grease
•
Keep the End Cap Prongs and Cable
Connection Receptacles dry
DO NOT:
•
Disconnect the cable under water
•
Leave an unconnected cable connection
underwater
•
Bend or twist the cable connection during
connection or disconnection
CONNECTION
The following sequence of photos outlines the connection process.
Figure 1-5: Applying dielectric grease and aligning the prongs
NOTE:
Ensure dielectric grease does not come in contact with electric prongs and receptacles.
DTS-12 End
Cap
Flange
Cable
Connection
Dielectric
Grease
Dielectric Grease
on End Cap Flange
Large prong aligned
with reference nipples