ES08
‐
15
Controller
v1.01.05
2022
‐
02
‐
03
FS
‐
Curtis
Page
13
Parameter
Set Value
Function
Password
To View
Password
To Edit
Shutdown
Pressure
8.50 bar
A shutdown alarm will be
activated if the discharge
air pressure reaches this
set value.
Note: The entire
compressor set will be
shut down.
User Factory
Schedule
Function
Enable with the slider button
pushed to the right-hand side and
displaying green colour as shown
in Figure 2.5; or
Disable with the slider pushed to
the left-hand side and displaying
grey colour only. Disable is the
standard setting.
Enables or disables the
three adjustable daily
on / off timers.
Note: These timers will
switch the compressor on
and off every day
provided the power
supply is energised.
User Service
Pressure
Band
Function
Enable with the slider button
pushed to the right-hand side and
displaying green colour as shown
in Figure 2.5; or
Disable with the slider pushed to
the left-hand side and displaying
grey colour only. Disable is the
standard setting.
Enables or disables
different start and stop
pressures to apply during
compressor operation in
each of the three
schedule timer periods.
User Service
Schedule
On and Off
Times
If the schedule function is enabled,
up to three different on / off timing
pairs can be specified for a single
24-hour period from 00:00 to
23:59. The schedule periods
should not overlap, for example:
#1 Schedule: 00:00 ~ 07:50
#2 Schedule: 08:00 ~ 15:50
#3 Schedule: 16:00 ~ 23:50
Adjustable daily on / off
timers.
Note: These timers will
switch the compressor on
and off every day
provided the power
supply is energised.
User Service