recommendations:
a) Do not operate the compressor with any of its maintenance access panels open or removed.
b) Before opening or removing any of its maintenance access panels or performing any maintenance
work on the compressor or connected pneumatic system: Switch off the unit; isolate and tag-out the
power supply; carefully release the residual air pressure from the internal piping and any external air
receiver tank and connected piping; and close the air outlet valve.
2.4
Temperature Menu Screen
The temperature menu is accessed via the system menu. Logging-in with the user password allows limited
access to view or edit the parameters; logging-in with the service password is necessary to edit most of the
set values. The temperature menu screen is shown in Figure 2.4.
Figure 2.4 – Temperature Menu Screen
Each of the temperature menu parameters is described in Table 2.3.
Table 2.3 – Temperature Menu Parameters
Parameter Set
Value
Function
Password
To View
Password
To Edit
Ambient
Temperature
Monitoring
Disable (with the
slider pushed to the
left-hand side and
displaying grey colour
only).
Provision for enabling or disabling the
ambient temperature warning and
shutdown alarms in the future. Note:
The compressor set does not have
this functionality.
User Service
Unit of
Temperature
°C
Temperature unit of measure.
User
Service