ES08
‐
15
Controller
v1.01.05
2022
‐
02
‐
03
FS
‐
Curtis
Page
16
Parameter
Set Value
Function
Password
To View
Password
To Edit
Drain On
4 seconds
The duration of the
condensate drain valve
being open each cycle.
User Service
Drain Off
600 seconds
The interval between
successive condensate drain
valve opening cycles during
which time the valve is
closed.
User Service
Fan Stop Delay
120 seconds
The run-on time for the
electric cooling fan after all
compressor modules have
stopped running.
User Service
Auto Restart
Delay
0 seconds is the standard
setting, which disables this
function.
The function can be enabled,
if required, by setting a value
of 1 ~ 1,200 seconds.
The elapsed time after a
power supply interruption is
rectified before the
compressor will
automatically restart if it was
previously operating in
automatic on / off mode.
User Service
#1 Main Motor
Test Output
#2 Main Motor
Test Output
#3 Main Motor
Test Output
[ES11 & ES15]
#4 Main Motor
Test Output
[ES15]
Fan Motor
Drain Valve
Push and hold the slider to
the right-hand side on (“I”)
position for 2 seconds to
initiate a momentary motor
rotation or drain valve
opening test.
The slider automatically
resets to the left-hand side off
(“O”) position after use.
For use during
commissioning or after
electrical repairs to check
the direction of motor
rotation or drain valve
function.
User Service