![Frymaster FilterQuick FQG30-T Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/frymaster/filterquick-fqg30-t/filterquick-fqg30-t_installation-operation-and-maintenance-manual_2340462046.webp)
5-10
Code
ERROR MESSAGE
EXPLANATION
E65
CLEAN OIB SENSOR – XXX F OR XXX C - CALL
SERVICE
Gas -The oil is back sensor does not detect
oil. Clean optional oil sensor.
E66
DRAIN VALVE OPEN – XXXF OR XXXC
Drain valve is opened during cooking.
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED
- CALL SERVICE
Controller is turned on when the SIB board
is not configured. Call service.
E68
OIB FUSE TRIPPED – CALL SERVICE
The VIB board OIB fuse has tripped and
didn’t reset. Call service.
E69
RECIPES NOT AVAILABLE – CALL SERVICE
The controller has not been programmed
with product recipes. Replace controller
with factory programmed controller.
E70
OQS TEMP HIGH
Oil temperature is too high for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
E71
OQS TEMP LOW
Oil temperature is too low for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
E72
TPM RANGE LOW
The TPM is too low for a valid OQS reading.
This may also be seen with fresh new oil.
The incorrect oil type may be selected in
the setup menu. The sensor may not be
calibrated for the oil type. See oil type chart
in instruction document 8197316. If issue
continues contact a FAS.
E73
TPM RANGE HIGH
The TPM reading is too high for a valid OQS
reading. Dispose the oil.
E74
OQS ERROR
The OQS has an internal error. If issue
continues contact a FAS.
E75
OQS AIR ERROR
The OQS is detecting air in the oil. Check
the O-rings and check/tighten prescreen
filter to ensure no air is entering the OQS
sensor. If issue continues contact a FAS.
E76
OQS ERROR
The OQS sensor has a communication
error. Check connections to the OQS
sensor. Power cycle the entire fryer battery.
If issue continues contact a FAS.
Содержание FilterQuick FQG30-T
Страница 47: ...THIS PAGE INTENTIONALLY LEFT BLANK...