5-9
Code
ERROR MESSAGE
EXPLANATION
E35
RETURN VALVE NOT CLOSED - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
Return valve was trying to close and
confirmation is missing
E36
VALVE INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
Valve Interface Board connections lost or
board failure. Call service.
E37
AUTOMATIC INTERMITTENT FILTRATION
PROBE FAILURE - FILTRATION DISABLED - CALL
SERVICE
AIF RTD reading out of range. Call service.
E39
CHANGE FILTER PAD
25-hour timer has expired or dirty filter
logic has activated. Change the filter paper
or pad.
E41
OIL IN PAN ERROR
The system detects that oil may be present
in the filter pan.
E42
CLOGGED DRAIN (Gas)
Vat did not empty during filtration. Ensure
the drain is not clogged and follow
prompts.
E43
OIL SENSOR FAILURE - CALL SERVICE
Oil level sensor may have failed. Call
service.
E44
RECOVERY FAULT
Recovery time exceeded maximum time
limit.
E45
RECOVERY FAULT – CALL SERVICE
Recovery time exceeded maximum time
limit for two or more cycles. Call service.
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL
SERVICE
SIB board 1 connection lost or board
failure. Call service.
E51
DUPLICATE BOARD ID - CALL SERVICE
Two or more controllers have the same
location ID. Call service.
E52
USER INTERFACE CONTROLLER ERROR - CALL
SERVICE
The controller has an unknown error. Call
service.
E53
CAN BUS ERROR - CALL SERVICE
Communications are lost between boards.
Call service.
E54
USB ERROR
USB connection lost during an update.
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL
SERVICE
SIB board 2 connection lost or board
failure. Call service.
E61
MISCONFIGURED ENERGY TYPE
The fryer is configured for the incorrect
energy type. Call service.
E62
VAT NOT HEATING – CHECK ENERGY SOURCE –
XXXF OR XXXC
The vat is not heating properly.
E63
RATE OF RISE
Rate of rise error occurred during a
recovery test. Ensure the oil level is at the
bottom oil level when cold and at the top
oil level line when at setpoint. On electric
fryers ensure the probe is not touching the
elements.
E64
FILTRATION INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
Filtration Interface Board connections lost
or board failure. Call service.