4.4 MONTHLY CHECKS AND SERVICE
4.4.1 Check FQ4000 Controller Set Point Accuracy
1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the
fryer temperature-sensing probe.
2. When the controller product icons are visible (indicating that the frypot contents are within the
cooking range), press the
button once to display the temperature and setpoint of the oil
as sensed by the temperature probe.
3. Note the temperature on the thermometer or pyrometer. Actual temperature and pyrometer
readings should be within ± 5ºF (3ºC) of each other. If not, contact a Factory Authorized Servicer
for assistance.
4.5 QUARTERLY CHECKS AND SERVICE
4.5.1 Clean Combustion Air Blower Assembly
1.
Disconnect the blower wiring harness and
remove the four blower mounting nuts.
(See Figure 2)
2.
Remove the blower from the fryer cabinet.
3.
Remove the blower shield or shield assembly.
4.
Remove the three fasteners that secure the blower motor
assembly to the blower housing, and separate the two
components. (See Figure 3)
Figure 3
5.
Wrap the motor with plastic wrap to
prevent water from entering it. Spray
degreaser or detergent on the blower
wheel and the blower housing. Allow it to
soak for five minutes. Rinse the wheel
and housing with hot tap water, then dry
with a clean cloth. (See Figure 4)
Wiring connection
Blower
Assembly Mounting Nuts
Remove these fasteners.
Figure 2
Blower Housing
Blower Wheel
Wrap the motor and wires
with plastic wrap or a
plastic bag.
Figure 4