![Frymaster FilterQuick FQG30-T Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/frymaster/filterquick-fqg30-t/filterquick-fqg30-t_installation-operation-and-maintenance-manual_2340462044.webp)
5-8
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Top off
reservoir won’t
fill.
A.
Incorrect setup procedure.
B.
Another function is in process.
C.
Dispose valve not completely
closed.
D.
Bulk oil tank is empty.
E.
Solenoid, pump or switch issue.
A.
Power cycle fryer by disconnecting
and reconnecting 5-pin bulk oil
control power cord on rear of fryer.
B.
If a filtration or any other filter menu
function is in process or FILTER
NOW? YES/NO, CONFIRM YES/NO, or
SKIM VAT are displayed, wait until the
process is complete and try again.
C.
Ensure the dispose valve handle is
pushed fully closed.
D. Call your bulk oil provider.
E.
Call you FAS for assistance.
Top off
reservoir or vat
filling slow.
Pump or line issues beyond the
scope of operator
troubleshooting.
Contact your bulk oil provider.
5.6 Error Log Codes
See section 1.13.2.1 in the FQ4000 Controller manual for instructions to access the
Error Log.
Code
ERROR MESSAGE
EXPLANATION
E13
TEMPERATURE PROBE FAILURE
TEMP Probe reading out of range. Call
service.
E16
HIGH LIMIT 1 EXCEEDED
High limit temperature is past more than
410°F (210°C), or in CE countries, 395°F
(202°C)
E17
HIGH LIMIT 2 EXCEEDED
High limit switch has opened.
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
Vat temperature exceeds 460°F (238°C) and
the high limit has failed to open.
Immediately disconnect power to the fryer
and call service.
E19
HEATING FAILURE – XXX F or XXX C
Heating Control latch circuit failed.
Heat Contactor failed to latch.
E25
HEATING FAILURE - BLOWER
The air pressure switch(s) failed to close.
E27
HEATING FAILURE - PRESSURE SWITCH - CALL
SERVICE
The air pressure switch has failed closed.
E28
HEATING FAILURE – XXX F or XXX C
The fryer has failed to ignite and has locked
out the ignition module.
E29
TOP OFF PROBE FAILURE - CALL SERVICE
ATO RTD reading out of range. Call service
E32
DRAIN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
Drain valve was trying to open and
confirmation is missing
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
Drain valve was trying to close and
confirmation is missing
E34
RETURN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
Return valve was trying to open and
confirmation is missing
Содержание FilterQuick FQG30-T
Страница 47: ...THIS PAGE INTENTIONALLY LEFT BLANK...