2-7
COUNTRIES CATEGORIES
GAS
PRESSURE
(MBAR)
AUSTRIA (AT)
II2H3B/P
G20 20
G30, G31
50
BELGIUM (BE)
I2E(R)B
G20, G25
20, 25
I3+
G30, G31
28-30, 37
BULGARIA (BG), CROATIA
(HR), FINLAND (FI),
ROMANIA (RO), SLOVENIA
(SI), TURKEY (TR)
II2H3B/P
G20 20
G30, G31
30
ESTONIA (EE),
LATVIA (LV)
I2H G20 20
FRANCE (FR)
G20, G25
20, 25
G30, G31
28-30, 37
II2Esi3P
G20, G25
20, 25
G31 50
GERMANY (DE)
II2ELL3B/P
G20, G25
20
G30, G31
50
I3P G31 50
HUNGARY (HU)
II2HS3B/P
G25 25
G30, G31
50
CYPRUS (CY), CZECH
REPUBLIC (CZ), GREECE
(GR),
IRELAND (IE), ITALY (IT),
PORTUGAL (PT),
SLOVAKIA (SK),
SPAIN (ES),
UNITED KINGDOM (GB)
II2H3+
G20 20
G30, G31
28-30, 37
LUXEMBOURG (LU)
II2E3B/P
G20, G25
20
G30, G31
50
NETHERLANDS (NL)
II2L3B/P
G25 25
G30, G31
30
ICELAND (IS)
MALTA (MT),
NORWAY (NO),
I3B/P G30,
G31
30
POLAND (PL)
II2E3B/P
G20, G25
20
G31 37
SWITZERLAND (CH)
II2H3+
G20 20
G30, G31
28-30, 37
II2H3B/P
G20 20
G30, G31
50
DENMARK (DK), SWEDEN
(SE), LITHUANIA (LT)
II2H3B/P
G20 20
G30, G31
30
I2H G20 20
NOTICE- Australia Only
The air pressure switch on the combustion blower should read: Full Vat units-
122pa (0.5 inches W.C.) and for Split Vat units-180pa (0.72 inches W.C.).
CE Approved Gas Categories by Country
Содержание FilterQuick FQG30-T