MODEL
IHS-1500
FUEL TYPES
#2 Fuel Oil / Diesel Fuel
NOZZLE
SIZE
6.50 USGPH
45’ B (SOLID)
PUMP
PRESSURE
High Fire
300 P.S.I.g *
Low Fire
140 P.S.I.g *
AIR SETTING
High Fire:
45
Low Fire:
30
Burner Slide Plate Setting: 2
APPROVAL
AGENCY
SPECIFICATIONS
* Pressure at the bleeder port. Subtract 10 PSI if measured at the pump discharge
port. See unit rating plate for exact specifications.
WARNING Read all the instructions before proceeding. Follow all instructions completely.
failure to follow these instructions could result in equipment malfunction, causing severe
personal injury, death or substantial property damage.
This equipment must be installed, adjusted and started only by a qualified service technician
– an Individual or agency, licensed and experienced with all the codes and ordinances, who
is responsible for the installation and adjustment of the equipment. The installation must
comply with all local codes and ordinances and with the National Fire Protection Standard
for Oil-Burning Equipment, NFPA 31 (or CSA B139-04).
NOTICE Concealed damage – If you discover damage to the burner or the controls
during Unpacking, notify the carrier at once and file the appropriate claim.
NOTICE High altitude installations – Accepted industry practice requires no derate of
Burner capacity up to 2000 feet above sea level. For altitudes higher than
2000 Feet, derate burner capacity 4% for each 1000 feet above sea level.
To the owner-