TABLE I. RECOMMENDED LUBRICATION
Frequency of re-lubrication depends upon operating conditions. The bearing operating temperature is the
best index for determining a re-lubrication schedule. The following chart gives the frequency of re-lubrication
based upon continuous operation for various operating temperatures and can be used as a satisfactory guide
for determining when bearings should be re-lubricated.
TABLE II. LUBRICATION FREQUENCY
Ball Bearings
Roller Bearings
Shaft Size
(inches)
Grease Charge
(ounces)
Shaft Size
(inches)
Grease Charge
(ounces)
1 – 1 ½
0.15
1 – ½ to 1 – 1 1/16
0.32
Speed
Temperature
Cleanliness
Greasing Interval
100 RPM
Up to 120 F
Clean
5 months
500 RPM
Up to 130 F
Clean
2 months
1000 RPM
Up to 210 F
Clean
2 weeks
1500 RPM
Over 150 F
Clean
Weekly
Any speed
Up to 150 F
Dirty
1 week to 1 month
Any speed
Over 150 F
Dirty
Daily to 1 week
Any speed
Any temperature
Very dirty
Daily to 1 week
Any speed
Any temperature
Extreme conditions
Daily to 1 week