INSTALL NOZZLE
Install the oil nozzle in the nozzle adaptor. Use a ¾” open-end wrench to steady the nozzle adaptor and
use a 5/8” open-end wrench to turn the nozzle. Tighten securely but do not over-tighten.
Verify that the oil tube assembly and electrodes are in good condition, with no cracks or damage.
WARNING
Failure to properly set and maintain the electrode and nozzle spacing dimensions can
cause incorrect burner ignition or poor combustion. This could result in severe personal
injury, death or substantial property damage.