MIG/MAG standard synergic welding
General
The MIG/MAG standard synergic welding process is only available in combination with the
Synergic control panel.
MIG/MAG stand-
ard synergic
welding
On Synergic B control panel:
Press the Material button to select the filler metal to be used.
Assignment of the SP position depends on the welding database used for the power
source.
Press the Wire diameter button to select the diameter of the wire electrode to be used.
Assignment of the SP position depends on the welding database used for the power
source.
Press the Shielding gas button to select the shielding gas to be used.
Assignment of the SP position depends on the welding database used for the power
source.
On Synergic A control panel:
Press the Process button to select the desired welding process:
MIG/MAG standard synergic welding
Press the Mode button to select the desired MIG/MAG mode:
2-step mode
4-step mode
Special 4-step mode
IMPORTANT!
Under certain circumstances, welding parameters that have been set
on a control panel of a system component (TR 2000 and TR 3000 remote control units
or robot interface) cannot be changed on the control panel of the wire-feed unit.
Press the Parameter selection buttons to select the welding parameters to be used to
specify the welding power:
Sheet thickness
Welding current
Wire feed speed
Welding voltage
Use the appropriate adjusting dial to set the relevant welding parameters.
The welding parameter values are shown in the digital display located above them.
All welding parameter set values remain stored until the next time they are changed. This
applies even if the power source is switched off and on again in the meantime.
1
2
3
4
5
6
7
Содержание VR 5000 noSpool
Страница 2: ...2...
Страница 4: ...4...
Страница 19: ...General information...
Страница 20: ......
Страница 25: ...Control elements and connections...
Страница 26: ......
Страница 41: ...Installation and commissioning...
Страница 42: ......
Страница 44: ...44 The VR 5000 noSpool without an integrated wirespool holder may only be set up and op erated in closed areas...
Страница 51: ...51 EN 1 2 1 2...
Страница 54: ...54 1 Contact pressure standard values U groove roll ers Steel 4 5 CrNi 4 5 Tubular cored electrodes 2 3 1 1...
Страница 58: ...58...
Страница 59: ...Welding...
Страница 60: ......
Страница 76: ...76 Number 3 Number 4 Number 5...
Страница 77: ...Setup settings...
Страница 78: ......
Страница 92: ...92...
Страница 93: ...Troubleshooting and maintenance...
Страница 94: ......
Страница 105: ...Technical data and settings tables...
Страница 106: ......
Страница 123: ...Appendix...
Страница 125: ...125...
Страница 126: ...126 E Euro connection Connectors F Fronius connection FSC Fronius system connection TW Tweco connection...
Страница 127: ...127 8 8 8 8 5 5 5 Motor Plate Alu 4R s Connector Motor...
Страница 128: ...128...
Страница 129: ...129...
Страница 130: ...130...
Страница 131: ...131...