NOTE!
Danger due to non-compliance with the permissible mains voltage tolerance.
Malfunctions and damage to property may result.
▶
For the electrolyte circulation option, a limited mains voltage tolerance of
207 V to 250 V applies compared to the battery charger.
The electrolyte circulation option delivers air into the battery via specially de-
signed capillary tubes. This results in an intensive mixing of the electrolyte. The
benefit is less battery heating, a longer battery life and less water loss during
charging.
If an error is detected due to a pump defect - or due to leaks in the connection to
the battery - the status code "Statecode 14" appears on the display. This defect
can be indicated as a common error by means of an external signal lamp, for ex-
ample.
Weight of the electrolyte circulation pump:
Air-Puls + air hose set
3 kW
2.5 kg (5.51 lb)
Air filter insert of the electrolyte circulation pump
Clean the air filter insert for the integrated air pump once a year. If there is a lot
of dust, shorten the cleaning interval accordingly. It is necessary to remove the
air filter insert for cleaning purposes. Remove the air filter by levering it out with
a slotted screwdriver and then reinstall it as follows:
NOTE!
Danger when using the air filter with battery chargers not designed for this pur-
pose.
This can result in damage to property.
▶
Only use the air filter with the battery chargers provided by the manufac-
turer.
58