Technical data
Selectiva 2 kW
WARNING!
An electric shock due to a residual current can be fatal.
Only use a type B residual current circuit breaker for the grid connection of the
device.
Mains voltage
1)
~ 230 V, ± 15%
Mains frequency
50/60 Hz
Mains fuse
2)
max. 16 A
Minimum cross-section of the grid lead
1.5 mm² (0.002325 in.²)
Safety class
I (with ground conductor)
Max. permitted grid impedance Z
max
on
PCC
3)
None
Standby consumption
4.9 W
EMC device class
B
Dimensions l x w x h
341 x 110 x 198 mm
(13.43 in. x 4.33 x 7.8 in.)
Pollution degree
3
Degree of protection
4)
IP21
Overvoltage category
II
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature
-25°C to +80°C
(-13°F to 176°F)
Relative humidity
max. 85%
Maximum altitude above sea level
2000 m (6561 ft.)
Mark of conformity
According to rating plate
Product standard
EN62477-1
1)
The device may be operated on grids that are grounded at the neutral
point.
2)
The thermal rating of the automatic circuit breaker must not exceed
30,000 A
2
s.
3)
Interface to a 230/400 V and 50 Hz public grid.
4)
For indoor use only, must not be exposed to rain or snow.
5)
At a high ambient temperature, a power reduction may occur (derating).