![Fronius Selectiva 4.0 2040 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/fronius/selectiva-4-0-2040/selectiva-4-0-2040_operating-instructions-manual_2339039029.webp)
WARNING!
Danger due to incorrect type of battery and incorrect charging settings.
This can result in severe personal injury and damage to property.
▶
Before starting the charging process, make sure that the correct type of bat-
tery is set on the battery charger.
▶
The following settings must be made for the individual types of battery be-
fore charging:
Charging curve
Nominal voltage (number of battery cells)
Battery capacity (Ah) or charging time (h)
Detailed information on the battery charger parameters can be found in the
"Configuration mode" section of the "Display" chapter.
NOTE!
Danger of damage to property due to heavy contamination of the charging plug
contacts.
Due to the increased contact resistance, overheating and subsequent destruction
of the charging plug can occur.
▶
Keep the charging plug contacts free of contamination and clean if neces-
sary.
1
Connect the mains plug of the battery charger to the electrical network.
A prompt appears, asking whether the correct parameters have been set for the
battery to be charged.
The display then appears in standard
mode. The display shows the battery
charger parameters:
-
Type of battery (e.g., Pb-WET)
-
Charging characteristic (e.g., IUI)
-
Nominal voltage (e.g., 48 V)
-
Capacity (e.g., 300 Ah)
-
Weekday, time, and date
The battery charger parameters are individually adjustable. Detailed information
on the battery charger parameters can be found in the "Configuration mode" sec-
tion of the "Display" chapter. Make sure that the battery to be charged corres-
ponds to the battery charger configuration.
2
Plug in the charging plug.
The charger detects the connected battery and starts charging. If the start-up
delay is activated, the charging process starts after the set delay time has
elapsed. Detailed information can be found in the "Configuration mode" section
of the "Display" chapter.
During the charging process, the display shows the following values:
-
Current charging current (A)
-
Current charging voltage (V)
-
Charge delivered (Ah)
-
Battery temperature with the "Temperature-controlled charging" option
-
Time (hh:mm) from start of charge
29
EN-US
Содержание Selectiva 4.0 2040
Страница 1: ...Operating Instructions Selectiva 4 0 2 3 kW 42 0426 0357 EA 008 10052022 EN US Operating instructions ...
Страница 2: ......
Страница 65: ...65 EN US ...
Страница 66: ...66 ...
Страница 67: ...67 EN US ...
Страница 68: ......