71
-St | oP- (where the power source is being operated with a robot interface or a
field bus)
Cause:
Robot not ready
Remedy:
Initialise “Robot ready” signal, initialise “Source error reset” signal (N.B.
“Source error reset” only available in conjunction with ROB 5000 and
field-bus coupler for robot control)
Displayed
service codes
(continued)
TT2200 /
MW1700/2200
power source
Power source does not function
Mains switch is ON, but indicators are not lit up
Cause:
There is a break in the mains lead; the mains plug is not plugged in
Remedy:
Check the mains supply lead, make sure that the mains plug is plugged in
Cause:
Mains outlet socket or plug is faulty
Remedy:
Exchange faulty components
Power source does not function
Mains switch is ON, but indicators are not lit up
Cause:
Mains fuse is faulty
Remedy:
Change the mains fuse
No welding current
Mains switch is ON, overtemperature indicator is lit up
Cause:
Overloading; the duty cycle has been exceeded
Remedy:
Do not exceed the duty cycle
Cause:
Thermostatic cut-out system has been tripped
Remedy:
Wait until the power source automatically comes back on after the end of
the cooling phase
Cause:
The fan in the power source is defective
Remedy:
Change the fan
No welding current
Mains switch is ON and indicators are lit up
Cause:
Grounding (earthing) connection is wrong
Remedy:
Check the grounding (earthing) connection and clamp for correct polarity
Cause:
There is a break in the current cable in the welding torch
Remedy:
Exchange the torch
The machine does not function when the torch trigger is pressed
Mains switch is ON and indicators are lit up
Cause:
The control plug is not plugged in
Remedy:
Plug in the control plug
Cause:
The welding torch or torch control lead is defective
Remedy:
Exchange the torch
Содержание MagicWave 1700
Страница 2: ......
Страница 4: ......
Страница 16: ...XII ud_fr_st_sv_00466 022002...
Страница 96: ......
Страница 108: ...XII ud_fr_st_sv_00467 052002...
Страница 188: ......
Страница 200: ...XII ud_fr_st_sv_00468 042002...
Страница 283: ...TransTIG 2200...
Страница 284: ...MagicWave 1700...
Страница 285: ...MagicWave 2200...
Страница 286: ...FK 2200...