56
Important!
The parameters Fd.1 to dt2 - outlined below - are only available in cases
where a cold-wire feeder has been connected up.
The parameters Fd.1 to dt2 are also described in connection with the “TIG cold-wire
welding” process (see the section headed “TIG welding”).
Fd.1
....
F
ee
d
er
1
... Wirefeed speed 1 (optional cold-wire feeder) ...
OFF / 0.1 m/min up to maximum (e.g. 22 m/min), factory setting: OFF
If the set-up parameter F-P (pulsing frequency) is set to “OFF”, the parameter Fd.1 is
used for constant wirefeed at constant welding amperage.
Fd.2
....
F
ee
d
er
2
... Wirefeed speed 2 (optional cold-wire feeder) ...
OFF / 0.1 m/min up to maximum (e.g. 22 m/min), factory setting: OFF
Important!
If F-P (pulsing frequency) is set to “OFF”, Fd.2 cannot be selected.
If a different value is set for each of the set-up parameters Fd.2 and F-P, the wirefeed
speed alternates between the values set for Fd.1 and Fd.2, in sync with the pulsing
frequency F-P of the welding current.
dt1
......
d
elay
t
ime
1
... Delay of the start of wirefeeding after the beginning of the main-
current phase I
1
(optional cold-wire feeder) ... OFF / 0.1 to 9.9 s
Factory setting: OFF
dt2
......
d
elay
t
ime
2
... Delay of the end of wirefeeding after the end of the main-current
phase I
1
(optional cold-wire feeder) ... OFF / 0.1 to 9.9 s
Factory setting: OFF
FAC
....
Fac
tory ... To reset the welding machine
Press and hold the Store button (13) for 2 s to reset the machine to the factory settings.
When the display reads “PrG”, the welding machine has been reset.
Important!
When the welding machine is reset, all the personal settings in Level 1 of
the set-up menu are lost. Jobs are not deleted when the welding machine is reset -
these are preserved. The parameter settings in the second level of the set-up menu
(2nd) are also not deleted.
2nd
..... Second level of the set-up menu (see “The set-up menu: Level 2”)
Available set-up
parameters
(continued)
Содержание MagicWave 1700
Страница 2: ......
Страница 4: ......
Страница 16: ...XII ud_fr_st_sv_00466 022002...
Страница 96: ......
Страница 108: ...XII ud_fr_st_sv_00467 052002...
Страница 188: ......
Страница 200: ...XII ud_fr_st_sv_00468 042002...
Страница 283: ...TransTIG 2200...
Страница 284: ...MagicWave 1700...
Страница 285: ...MagicWave 2200...
Страница 286: ...FK 2200...