11
Balance
(only with TIG-AC) ... -5 / +5, factory setting: 0
-5 highest fusing power,
lowest cleaning action
+5 highest cleaning action,
lowest fusing power
Electrode diameter
............... 0 to 4.0 mm, factory setting: 2.4 mm
Available parameters where 4-step mode (3) has been selected:
Starting current I
S
................. 0 to 100 % of main current I
1
Factory setting: 35%
Important!
The starting current I
S
is saved separately for the “TIG-AC welding” and
“TIG DC- welding” operating modes.
Upslope t
up
............................ 0.0 to 9.9 s, factory setting: 0.1 s
Important!
The upslope
t
up
is saved separately for the 2-step and 4-step operating
modes.
Main current I
1
...................... MagicWave 1700: 3 to 170 A
MagicWave 2200: 3 to 220 A
Reduced current I
2
............... 0 to 100 % of main current I
1
Factory setting: 50%
Downslope t
down
.................... 0.0 to 9.9 s, factory setting: 1 s
Important!
The downslope
t
down
is saved separately for the 2-step and 4-step
operating modes.
Final current I
E
...................... 0 to 100 % of main current
Factory setting: 30 %
Balance
(only with TIG-AC) . -5 / +5, factory setting: 0
-5 .... highest fusing power,
lowest cleaning action
+5 ... highest cleaning action,
lowest fusing power
Electrode diameter
............... 0 to 4.0 mm, factory setting: 2.4 mm
Available parameters where “Job mode” (4) has been selected:
In “Job mode”, the parameters that apply to the operating mode that has been
stored in the selected job are made available. In addition, the following parameter is
also available:
Job number
.......................... for selecting the desired job
Available parameters where the “Rod electrode (MMA) welding” mode (5) has been
selected:
Main current I
1
...................... MagicWave 1700: 10 to 140 A
MagicWave 2200: 10 to 180 A
MagicWave 1700/
2200 control
panel
(continued)
Содержание MagicWave 1700
Страница 2: ......
Страница 4: ......
Страница 16: ...XII ud_fr_st_sv_00466 022002...
Страница 96: ......
Страница 108: ...XII ud_fr_st_sv_00467 052002...
Страница 188: ......
Страница 200: ...XII ud_fr_st_sv_00468 042002...
Страница 283: ...TransTIG 2200...
Страница 284: ...MagicWave 1700...
Страница 285: ...MagicWave 2200...
Страница 286: ...FK 2200...