106
FCO
Feeder control - Wirefeeder cut-out (wire end sensor option)
Unit
-
Setting range
OFF/ON/noE
Factory setting
OFF
OFF
The power source halts the wirefeeder when the wire end sensor
is triggered. "Err|056" appears on the display.
ON
When the wire end sensor is triggered, the power source only
halts the wirefeeder after the current weld seam has been com
-
pleted. "Err|056" appears on the display.
noE
The power source does not halt the wirefeeder when the wire end
sensor is triggered. The wire end alarm is not displayed and is
only transmitted to the robot control via the field bus.
IMPORTANT!
The "noE" setting only functions in conjunction with the field bus applica
-
tions. Robot interfaces ROB 4000/5000 do not support this function.
COr
Correction - Gas correction ("Digital gas control" option)
Unit
-
Setting range
AUT / 1.0 - 10.0
Factory setting
Aut
IMPORTANT!
Please refer to "Digital gas control" Operating Instructions for more de
-
tailed explanations of the "COr" parameter.
Содержание MagicWave 1700 Job
Страница 2: ...2...
Страница 18: ...18...
Страница 19: ...General information...
Страница 20: ......
Страница 25: ...Control elements and connections...
Страница 26: ......
Страница 46: ...46...
Страница 47: ...Installation and commissioning...
Страница 48: ......
Страница 57: ...Welding...
Страница 58: ......
Страница 66: ...66 Special 4 step mode variant 6 0 5 s 0 5 s 0 5 s 0 5 s GPr tdown G L G H tup I t I1 IS IE I1 I1 I2 0 5 s...
Страница 86: ...86...
Страница 87: ...Setup settings...
Страница 88: ......
Страница 121: ...Troubleshooting and maintenance...
Страница 122: ......
Страница 131: ...Appendix...
Страница 132: ......
Страница 146: ...146...
Страница 147: ...147 EN...