94
dYn
dynamic - arc force dynamic correction
Unit
-
Setting range
0 - 100
Factory setting
20
For further information on the dYn parameter, see the rod electrode set-up menu.
HCU
Hot-Start current
Unit
%
Setting range
0 - 200
Factory setting
150
dt1
delay time 1 - time by which the start of wirefeeding is delayed after the beginning of main
current phase I
1
(cold wire-feed unit option)
Unit
s
Setting range
OFF / 0.1 - 9.9
Factory setting
OFF
dt2
delay time 2 - Delay in the end of wirefeeding from the end of main current phase I
1
(cold wire-feed unit option)
Unit
s
Setting range
OFF / 0.1 - 9.9
Factory setting
OFF
Fdi
Feeder inching - Feeder inching speed (cold wire-feed unit option)
Unit
m/min
ipm.
Setting range
1,0 - max.
39.37 - max.
Factory setting
5
197
Fdb
Feeder backward - wire withdrawal (cold wire-feed unit option)
Unit
mm
in.
Setting range
OFF / 1 - 50
OFF / 0.04 - 1.97
Factory setting
OFF
OFF
For further information on the Fdb parameter, see the TIG set-up menu.
Содержание MagicWave 1700 Job
Страница 2: ...2...
Страница 18: ...18...
Страница 19: ...General information...
Страница 20: ......
Страница 25: ...Control elements and connections...
Страница 26: ......
Страница 46: ...46...
Страница 47: ...Installation and commissioning...
Страница 48: ......
Страница 57: ...Welding...
Страница 58: ......
Страница 66: ...66 Special 4 step mode variant 6 0 5 s 0 5 s 0 5 s 0 5 s GPr tdown G L G H tup I t I1 IS IE I1 I1 I2 0 5 s...
Страница 86: ...86...
Страница 87: ...Setup settings...
Страница 88: ......
Страница 121: ...Troubleshooting and maintenance...
Страница 122: ......
Страница 131: ...Appendix...
Страница 132: ......
Страница 146: ...146...
Страница 147: ...147 EN...